The inerting systems use an inert gas generator to supply inert make-up gas instead of air. This procedure is often referred to as inerting. Technically, the procedure ensures that the atmosphere in the tank's headspace remains unignitable. The gas mixture in the headspace is not inert per se, it's just unignitable. Because of its content of ...
The inerting systems will probably prevent 8 of those 9 probable explosions, the FAA said. Before the inerting system rule was proposed, Boeing stated that it would install its own inerting system on airliners it manufactures beginning in 2005. Airbus had argued that its planes' electrical wiring made the inerting system an unnecessary expense.
Inert gas can also be used to purge the tank of the volatile atmosphere in preparation for gas freeing - replacing the atmosphere with breathable air - or vice versa. The flue gas system uses the boiler exhaust as its source, so it is important that the fuel/air ratio in the boiler burners is properly regulated to ensure that high-quality inert ...
Because an inert purge gas is used, the purge procedure may (erroneously) be referred to as inerting in everyday language. This confusion may lead to dangerous situations. Carbon dioxide is a safe inert gas for purging. Carbon dioxide is an unsafe inert gas for inerting, as it may ignite the vapors and result in an explosion. [2]
The hot, dirty gas is then passed through a scrubbing tower which cleans and cools it using seawater. This gas is then delivered to cargo tanks to prevent explosion of flammable cargo. [1] This generator is sometimes confused with flue gas systems, which draw inert gas from the boiler systems of the ship. Flue gas systems do not have a burner ...
Purging is accomplished by pumping inert gas into the tank until hydrocarbons have been sufficiently expelled. Next the tank is gas freed which is usually accomplished by blowing fresh air into the space with portable air powered or water powered air blowers. "Gas freeing" brings the oxygen content of the tank up to 20.8% O 2. The inert gas ...
For instance, to safely fill a new container or a pressure vessel with flammable gases, the atmosphere of normal air (containing 20.9 volume percent of oxygen) in the vessel would first be flushed (purged) with nitrogen or another non-flammable inert gas, thereby reducing the oxygen concentration inside the container. When the oxygen ...
From the cases analyzed, it was determined that the over pressure of inert gas systems can constitute a risk even in the presence of a system designed and built according to technical standards. [5] On September 20, 2018, two people died after an inert gas leak from a fire suppression system located in the State Archives in Arezzo (Italy). [ 6 ]