Search results
Results from the WOW.Com Content Network
Pre-tensioned concrete is a variant of prestressed concrete where the tendons are tensioned prior to the concrete being cast. [ 1 ] : 25 The concrete bonds to the tendons as it cures , following which the end-anchoring of the tendons is released, and the tendon tension forces are transferred to the concrete as compression by static friction .
The Freyssinet Test Arch (in French Arche d'essai Freyssinet) is a prestressed concrete arch built in 1909 in Moulins, Allier by Eugène Freyssinet1. [1] Its purpose was to test the resistance of this material to traction exerted on very flat and long-range arches. [1]
The inventor of prestressed concrete is Eugene Freyssinet of France. Lin retired in 1976 to work full-time at T.Y. Lin International , a firm he founded in 1954. After selling that firm, he left it to found Lin Tung-Yen China on June 1, 1992, which oversees engineering projects in China.
Prestressed concrete cylinder pipe (PCCP) is a common variety of large-diameter concrete pressure pipe used for transporting water and wastewater. PCCP is typical manufactured according to the American Water Works Association (AWWA) standard C304. [ 1 ]
Naturally precompressed exterior wall of Colosseum, Rome Cable-stayed prestressed concrete bridge over Yangtze river. In structural engineering, a prestressed structure is a load-bearing structure whose overall integrity, stability and security depend, primarily, on prestressing: the intentional creation of permanent stresses in the structure for the purpose of improving its performance under ...
A precast concrete walled house under construction An example of low-quality precast concrete with exposed dowels, connectors, indications of cracks, and malformations, even during its installation, Barangay Lantic, Carmona, Cavite, Philippines Interior view of the walls, supports, and roof of a precast commercial shop in Williston, North Dakota, US.
The Precast/Prestressed Concrete Institute (PCI) published the double tee load capacity calculation (load tables) for the first time in the PCI Design Handbook in 1971. The load tables use the code to identify double tee span type by using the width in feet, followed by "DT", followed by depth in inches, for example, 4DT14 is for 4-foot (1.2 m ...
EN 206+A2 Concrete – Part 1: Specification, performance, production and conformity (formerly EN 206 and EN 206-1 and EN 206+A1) is a European standard elaborated by the CEN/TC 104 "Concrete and related products" technical committee.