  1. Results from the WOW.Com Content Network
  2. Motor capacitor - Wikipedia

    en.wikipedia.org/wiki/Motor_capacitor

    A typical motor start capacitor. A motor capacitor [1] [2] is an electrical capacitor that alters the current to one or more windings of a single-phase alternating-current induction motor to create a rotating magnetic field. [citation needed] There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run ...

  3. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    For a machine to run as an asynchronous generator, capacitor bank must supply minimum 4567 / 3 phases = 1523 VAR per phase. Voltage per capacitor is 440 V because capacitors are connected in delta. Capacitive current Ic = Q/E = 1523/440 = 3.46 A Capacitive reactance per phase Xc = E/Ic = 127 Ω. Minimum capacitance per phase:

  4. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    A feature in the generator mode in parallel to the grid is that the rotor speed is higher than in the driving mode. Then active energy is being given to the grid. [2] Another disadvantage of the induction motor generator is that it consumes a significant magnetizing current I 0 = (20–35)%.

  5. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    A specific model of a generator operated as a standby generator may only need to operate for a few hours per year, but the same model operated as a prime power generator must operate continuously. When running, the standby generator may be operated with a specified - e.g. 10% overload that can be tolerated for the expected short running time.

  6. Switched reluctance motor - Wikipedia

    en.wikipedia.org/wiki/Switched_reluctance_motor

    The same electromechanical design can be used in a generator. The load is switched to the coils in sequence to synchronize the current flow with the rotation. Such generators can be run at much higher speeds than conventional types as the armature can be made as one piece of magnetisable material, as a slotted cylinder. [16]

  7. Doubly fed electric machine - Wikipedia

    en.wikipedia.org/wiki/Doubly_fed_electric_machine

    The doubly fed generator rotors are typically wound with 2 to 3 times the number of turns of the stator. This means that the rotor voltages will be higher and currents respectively lower. Thus in the typical ±30% operational speed range around the synchronous speed, the rated current of the converter is accordingly lower which leads to a lower ...

  8. AC motor - Wikipedia

    en.wikipedia.org/wiki/AC_motor

    Schematic of a capacitor start motor. A capacitor start motor is a split-phase induction motor with a starting motor capacitor inserted in series with the startup winding, creating an LC circuit which produces a greater phase shift (and so, a much greater starting torque) than both split-phase and shaded pole motors. This motor has a ...

  9. Applications of capacitors - Wikipedia

    en.wikipedia.org/wiki/Applications_of_capacitors

    The start capacitor is typically mounted to the side of the motor housing. These are called capacitor-start motors, and have relatively high starting torque. There are also capacitor-run induction motors which have a permanently connected phase-shifting capacitor in series with a second winding. The motor is much like a two-phase induction motor.