Ads
related to: how scada communicate with plc companies
Search results
Results from the WOW.Com Content Network
PACs are deployed in SCADA systems to provide RTU and PLC functions. In many electrical substation SCADA applications, "distributed RTUs" use information processors or station computers to communicate with digital protective relays, PACs, and other devices for I/O, and communicate with the SCADA master in lieu of a traditional RTU.
DF-1 - used by Allen-Bradley ControlLogix, CompactLogix, PLC-5, SLC-500, and MicroLogix class devices; DNP3 - a protocol used to communicate by industrial control and utility SCADA systems; DirectNet – Koyo / Automation Direct proprietary, yet documented PLC interface; EtherCAT; Ethernet Global Data (EGD) – GE Fanuc PLCs (see also SRTP)
The DNP3 protocol is also referenced in IEEE Std. IEEE 1379-2000, which recommends a set of best practices for implementing modern SCADA Master-RTU/IED communication links. These include not just encryption but other practices that enhance security against well known intrusion methods.
A feedback control loop is directly controlled by the RTU or PLC, but the SCADA software monitors the overall performance of the loop. For example, a PLC may control the flow of cooling water through part of an industrial process to a set point level, but the SCADA system software will allow operators to change the set points for the flow.
Actuator Sensor Interface (AS-Interface or ASi) is an industrial networking solution (Physical Layer, Data access Method and Protocol) used in PLC, DCS and PC-based automation systems. It is designed for connecting simple field I/O devices (e.g. binary ON/OFF devices such as actuators, sensors, rotary encoders, analog inputs and outputs, push ...
A programmable logic controller (PLC) or programmable controller is an industrial computer that has been ruggedized and adapted for the control of manufacturing processes, such as assembly lines, machines, robotic devices, or any activity that requires high reliability, ease of programming, and process fault diagnosis.
OPC specifies the communication of real-time plant data between control devices from different manufacturers. After the initial release in 1996, the OPC Foundation was created to maintain the standards. [1] Since OPC has been adopted beyond the field of process control, the OPC Foundation changed its name to Open Platform Communications in 2011 ...
The first industrial control computer system was built 1959 at the Texaco Port Arthur, Texas, refinery with an RW-300 of the Ramo-Wooldridge Company. [4] In 1975, both Yamatake-Honeywell [5] and Japanese electrical engineering firm Yokogawa introduced their own independently produced DCS's - TDC 2000 and CENTUM systems, respectively. US-based ...