enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  3. Operative temperature - Wikipedia

    en.wikipedia.org/wiki/Operative_temperature

    Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...

  4. Radiant heating and cooling - Wikipedia

    en.wikipedia.org/wiki/Radiant_heating_and_cooling

    Radiant heating as a technology is more narrowly defined. It is the method of intentionally using the principles of radiant heat to transfer radiant energy from an emitting heat source to an object. Designs with radiant heating are seen as replacements for conventional convection heating as well as a way of supplying confined outdoor heating.

  5. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  6. How much more will it cost to heat your home this winter? - AOL

    www.aol.com/much-more-cost-heat-home-222057750.html

    Heating costs for natural gas are up just over 3%, for an average cost of $634 for the winter period, compared with $615 for 2023-2024. Costs are expected to rise only modestly in line with ...

  7. Passive daytime radiative cooling - Wikipedia

    en.wikipedia.org/wiki/Passive_daytime_radiative...

    The average PDRC has an estimated cooling power of ~100-150 W/m 2, proportional to the exposed surface area. [4] [19] PDRC applications are deployed as sky-facing surfaces. [14] Low-cost scalable PDRC materials with potential for mass production include coatings, thin films, metafabrics, aerogels, and biodegradable surfaces.

  8. Underfloor heating - Wikipedia

    en.wikipedia.org/wiki/Underfloor_heating

    Convective heat transfer with underfloor systems is much greater when the system is operating in a heating rather than cooling mode. [60] Typically with underfloor heating the convective component is almost 50% of the total heat transfer and in underfloor cooling the convective component is less than 10%. [61]

  9. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...