enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    As more architecture incorporated mechanical ventilation, the cost of outdoor air ventilation came under some scrutiny. In 1973, in response to the 1973 oil crisis and conservation concerns, ASHRAE Standards 62-73 and 62–81) reduced required ventilation from 10 CFM (4.76 L/s) per person to 5 CFM (2.37 L/s) per person. In cold, warm, humid, or ...

  3. Attic fan - Wikipedia

    en.wikipedia.org/wiki/Attic_fan

    An attic fan installed underneath a roof. A powered attic ventilator, or attic fan, is a ventilation fan that regulates the heat level of a building's attic by exhausting hot air. A thermostat is used to automatically turn the fan off and on, while sometimes a manual switch is used. An attic fan can be gable mounted or roof mounted. Additional ...

  4. Passive solar building design - Wikipedia

    en.wikipedia.org/wiki/Passive_solar_building_design

    If vents are left open at night (or on cloudy days), a reversal of convective airflow will occur, wasting heat by dissipating it outdoors. Vents must be closed at night so radiant heat from the interior surface of the storage wall heats the indoor space. Generally, vents are also closed during summer months when heat gain is not needed.

  5. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality .

  6. Radiant barrier - Wikipedia

    en.wikipedia.org/wiki/Radiant_barrier

    When laying a radiant barrier over the insulation on the attic floor, it is possible for dust to accumulate on the top side. Many factors like dust particle size, dust composition and the amount of ventilation in the attic affect how dust accumulates and thus the ultimate performance of a radiant barrier in an attic.

  7. Heat and smoke vent - Wikipedia

    en.wikipedia.org/wiki/Heat_and_smoke_vent

    The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...

  8. Infrared lamp - Wikipedia

    en.wikipedia.org/wiki/Infrared_lamp

    Infrared heating uses infrared lamps, commonly called heat lamps, to transmit infrared radiation to the body that is being heated. When a body with a large surface area needs to be heated, an array of infrared lamps is often used. The lamp commonly contains an incandescent bulb that produces infrared radiation.

  9. Attic - Wikipedia

    en.wikipedia.org/wiki/Attic

    One common code requirement is that the total area of attic vents be equal to or greater than 1/150 of the floor area of the attic, with 50 percent or more of the vent area located in the upper portion of the attic. Vents and louvers should face away from prevailing winds to keep out driven rain. Soffit vents under the eaves normally provide ...