For example, a surface ceiling light is shown by one symbol, a recessed ceiling light has a different symbol, and a surface fluorescent light has another symbol. Each type of switch has a different symbol and so do the various outlets. There are symbols that show the location of smoke detectors, the doorbell chime, and thermostat.
A receptacle tester being used to check for some types of improper wiring of an outlet. For this particular tester, proper wiring is indicated by the two yellow lights. The outlet tester checks that each contact in the outlet appears to be connected to the correct wire in the building's electrical wiring. It can identify several common wiring ...
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...
In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.
Each phase of the circuit is run in a separate grounded metal enclosure. The only fault possible is a phase-to-ground fault, since the enclosures are separated. This type of bus can be rated up to 50,000 amperes and up to hundreds of kilovolts (during normal service, not just for faults), but is not used for building wiring in the conventional ...
In electric power distribution networks, a fault indicator is a device which provides visual or remote indication of a fault on the electric power system. Also called a faulted circuit indicator (FCI), [1] the device is used in electric power distribution networks as a means of automatically detecting and identifying faults to reduce outage time.
a database of similar faults which have been resolved in identical or similar equipment [3] precautionary changes, without attempting to pinpoint the fault. For example, electrolytic capacitors subject to high ripple currents can be changed as a routine measure, without bothering to troubleshoot the fault at all. Connectors can be disconnected ...
There are times when a simple continuity test fails to reveal the problem. For example, vibration-induced problems in automobile wiring can be extremely difficult to detect because a short or open is not maintained long enough for a standard tester to respond. In these applications a latching continuity tester is used.