Search results
Results from the WOW.Com Content Network
This means that the generally inferior flow of a reverse-flow head is less of a disadvantage. In the early days of turbo charging a reverse-flow head allowed the compressor outlet of a turbocharger to blow directly into the inlet manifold with either a blow-through or draw-through carburettor and no intercooler. This allowed the use of shorter ...
Backflow occurs for one of two reasons, either back pressure or back siphonage. [1] Back pressure is the result of a higher pressure in the system than in its supply, i.e. the system pressure has been increased by some means. This may occur in unvented heating systems, where thermal expansion increases the pressure.
[4] [5] [6] A generalized model of the flow distribution in channel networks of planar fuel cells. [6] Similar to Ohm's law, the pressure drop is assumed to be proportional to the flow rates. The relationship of pressure drop, flow rate and flow resistance is described as Q 2 = ∆P/R. f = 64/Re for laminar flow where Re is the Reynolds number.
Thus the return section of water and oil tunnels does not need any flow management; typically it is just a pipe sized for the pump and desired flow speeds. The upstream section of a water tunnels generally consists of a pipe (outlet from the pump) with several holes along its side and with the end open followed by a series of coarse and fine ...
Showing outlet flow velocity in a pipe. In outlet boundary conditions, the distribution of all flow variables needs to be specified, mainly flow velocity. This can be thought as a conjunction to inlet boundary condition. This type of boundary conditions is common and specified mostly where outlet velocity is known. [1]
The lower figure shows flow in the unimpeded direction (blue). One computational fluid dynamics simulation of Tesla valves with two and four segments showed that the flow resistance in the blocking (or reverse) direction was about 15 and 40 times greater, respectively, than the unimpeded (or forward) direction. [11]
There are two check valves, often ball check valves, attached to the pump head, one at the inlet line and the other at the outlet line. The inlet valve allows flow from the inlet line to the piston chamber, but not in the reverse direction. The outlet valve allows flow from the chamber to the outlet line, but not in reverse.
Air flow conditions must be measured at two locations, across the test piece and across the metering element. The pressure difference across the test piece allows the standardization of tests from one to another. The pressure across the metering element allows calculation of the actual flow through the whole system.