Communication is digital and bi-directional between the controller (primary) and the boiler (secondary). Various commands and kinds of information can be transferred; however, the most basic command is to set the boiler's target water temperature. OpenTherm makes use of a traditional untwisted 2-wire cable between controller and boiler.
If both TRV and thermostat set temperatures were set equally, unpredictable behaviour may occur with both devices attempting to control the room temperature. Therefore, in case of installing a TRV and an air temperature based boiler thermostat in the same room, the TRV should be set to a higher temperature than the room thermostat. [citation ...
A boiler is a closed vessel in which fluid (generally water) is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, [1] [page needed] [2] [page needed] including water heating, central heating, boiler-based power generation, cooking, and sanitation.
The boiler will also fire (regardless of thermostat state) when the boiler water temperature goes below a range around the low limit, ensuring that the boiler water temperature remains above a certain point. The low limit is intended for tankless domestic hot water; it ensures that boiler water is always warm enough to heat the domestic hot water.
By using non-condensing modulating boiler. By setting the controls (thermostats or controller with temperature sensors) with greater temperature differentials between STOP and START. At Non-Condensing Boilers make provisions so that minimum return water temperature of 130 °F (54 °C) to 150 °F (66 °C) to the boiler to avoid fireside corrosion.
A tempering valve mixes enough cold water with the hot water from the heater to keep the outgoing water temperature fixed at a more moderate temperature, often set to 50 °C (122 °F). Without a tempering valve, reduction of the water heater's setpoint temperature is the most direct way to reduce scalding.
The lower the return temperature to the boiler the more likely it will be in condensing mode. If the return temperature is kept below approximately 55 °C (131 °F), the boiler should still be in condensing mode making low temperature applications such as radiant floors and even old cast iron radiators a good match for the technology.
The boiler heats water to a temperature controlled by a thermostat. The water then flows (either by natural circulation or by a pump) to radiators in the rooms which are to be heated. Water also flows through a coil in the hot water tank to heat a separate mass of water for bathing, etc.