enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    Air streams are mixed to save energy and improve energy efficiency by partially recirculating conditioned air.. The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1]

  3. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer. A zone damper (also known as a Volume Control Damper or VCD) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system. In order to ...

  4. Sound attenuator - Wikipedia

    en.wikipedia.org/wiki/Sound_attenuator

    A sound attenuator, or duct silencer, sound trap, or muffler, is a noise control acoustical treatment of Heating Ventilating and Air-Conditioning (HVAC) ductwork designed to reduce transmission of noise through the ductwork, either from equipment into occupied spaces in a building, or between occupied spaces. [1] [2]

  5. Butterfly valve - Wikipedia

    en.wikipedia.org/wiki/Butterfly_valve

    Butterfly valve with actuator electric valve - An electrically actuated butterfly valve is a quarter-turn valve controlled by an electric motor. It offers fast and precise flow regulation, remote operation, and versatility for various applications.

  6. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Smoke dampers and fire dampers are found in ductwork where the duct passes through a firewall or firecurtain. Smoke dampers are driven by a motor, referred to as an actuator. A probe connected to the motor is installed in the run of the duct and detects smoke, either in the air which has been extracted from or is being supplied to a room, or ...

  7. Industrial furnace - Wikipedia

    en.wikipedia.org/wiki/Industrial_furnace

    The stack damper contained within works like a butterfly valve and regulates draft (pressure difference between air intake and air exit) in the furnace, which is what pulls the flue gas through the convection section. The stack damper also regulates the heat lost through the stack.

  8. Variable air volume - Wikipedia

    en.wikipedia.org/wiki/Variable_air_volume

    The fan maintains a constant static pressure in the discharge duct regardless of the position of the VAV box. Therefore, as the box closes, the fan slows down or restricts the amount of air going into the supply duct. As the box opens, the fan speeds up and allows more air flow into the duct, maintaining a constant static pressure. [11]

  9. Smoke damper - Wikipedia

    en.wikipedia.org/wiki/Smoke_damper

    Smoke damper may be used to prevent the spread of smoke from the space of fire origin to other spaces in the same building. A combination of fans and dampers can exhaust smoke from an area while pressurizing the smoke-free areas around the affected area (inhibiting smoke infiltration into additional areas).