enow.com Web Search

  1. Ad

    related to: detectors used in mass spectrometry practice problems

Search results

  1. Results from the WOW.Com Content Network
  2. Ion-to-photon detector - Wikipedia

    en.wikipedia.org/wiki/Ion-to-photon_detector

    Ion-to-photon detectors may also detect ions with a mass of up to around 20,000 Da, better than microchannel plates. However, the resolution of the mass spectrum from an IPD equipped spectrometer is slightly lower. The noise in the spectrum, which may come from unfocused, slow speed ions, is also slightly higher.

  3. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a mass spectrum, a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used in many different fields and is applied to pure samples as well as complex mixtures.

  4. Daly detector - Wikipedia

    en.wikipedia.org/wiki/Daly_detector

    A Daly detector is a gas-phase ion detector that consists of a metal "doorknob", a scintillator (phosphor screen) and a photomultiplier. [1] It was named after its inventor Norman Richard Daly. Daly detectors are typically used in mass spectrometers .

  5. Microchannel plate detector - Wikipedia

    en.wikipedia.org/wiki/Microchannel_plate_detector

    A microchannel plate within a Finnigan MAT 900 sector mass spectrometer position-and-time-resolved-ion-counting (PATRIC) scanning array detector. An external voltage divider is used to apply 100 volts to the acceleration optics (for electron detection), each MCP, the gap between the MCPs, the backside of the last MCP, and the collector .

  6. Helium mass spectrometer - Wikipedia

    en.wikipedia.org/wiki/Helium_mass_spectrometer

    Helium is used as a tracer because it penetrates small leaks rapidly. Helium also has the properties of being non-toxic, chemically inert and present in the atmosphere only in minute quantities (5 ppm). Typically a helium leak detector will be used to measure leaks in the range of 10 −5 to 10 −12 Pa·m 3 ·s −1.

  7. Gas chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography–mass...

    The mass spectrometry process normally requires a very pure sample while gas chromatography using a traditional detector (e.g. Flame ionization detector) cannot differentiate between multiple molecules that happen to take the same amount of time to travel through the column (i.e. have the same retention time), which results in two or more ...

  8. Orbitrap - Wikipedia

    en.wikipedia.org/wiki/Orbitrap

    Orbitrap-based mass spectrometers are used in proteomics [13] [16] and are also used in life science mass spectrometry such as metabolism, metabolomics, [17] environmental, [18] food and safety analysis. [19]

  9. Liquid chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Liquid_chromatography...

    The mass spectrum can be used to determine the mass of the analytes, their elemental and isotopic composition, or to elucidate the chemical structure of the sample. [5] MS is an experiment that must take place in gas phase and under vacuum (1.33 * 10 −2 to 1.33 * 10 −6 pascal).

  1. Ad

    related to: detectors used in mass spectrometry practice problems