Search results
Results from the WOW.Com Content Network
Part 3 of IEC 61131 deals with basic software architecture and programming languages of the control program within PLC. It defines three graphical and two textual programming language standards: Ladder diagram (LD), graphical; Function block diagram (FBD), graphical; Structured text (ST), textual
For example, the sample diagram does not indicate the physical type of connection between the PCs and the switch, but since a modern LAN is depicted, Ethernet may be assumed. If the same style of line was used in a WAN (wide area network) diagram, however, it may indicate a different type of connection.
The input/output arrangements may be built into a simple PLC, or the PLC may have external I/O modules attached to a fieldbus or computer network that plugs into the PLC. The functionality of the PLC has evolved over the years to include sequential relay control, motion control, process control , distributed control systems , and networking .
Function Block Diagram is one of five languages for logic or control configuration [2] supported by standard IEC 61131-3 for a control system such as a programmable logic controller (PLC) or a Distributed Control System (DCS). The other supported languages are ladder logic, sequential function chart, structured text, and instruction list.
Ladder diagrams were once the only way to record programmable controller programs, but today, other forms are standardized in IEC 61131-3. For example, instead of the graphical ladder logic form, there is a language called Structured text, which is similar to C, within the IEC 61131-3 standard.
Block diagram of a basic computer with uniprocessor CPU. Black lines indicate control flow, whereas red lines indicate data flow. Arrows indicate the direction of flow. In computer science and computer engineering, computer architecture is a description of the structure of a computer system made from component parts. [1]
Actuator Sensor Interface (AS-Interface or ASi) is an industrial networking solution (Physical Layer, Data access Method and Protocol) used in PLC, DCS and PC-based automation systems. It is designed for connecting simple field I/O devices (e.g. binary ON/OFF devices such as actuators, sensors, rotary encoders, analog inputs and outputs, push ...
DF-1 - used by Allen-Bradley ControlLogix, CompactLogix, PLC-5, SLC-500, and MicroLogix class devices; DNP3 - a protocol used to communicate by industrial control and utility SCADA systems; DirectNet – Koyo / Automation Direct proprietary, yet documented PLC interface; EtherCAT; Ethernet Global Data (EGD) – GE Fanuc PLCs (see also SRTP)