  2. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  3. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  4. Vacuum insulated panel - Wikipedia

    en.wikipedia.org/wiki/Vacuum_insulated_panel

    Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value, 154 millimetres (6 in) of rockwool or 84 millimetres (3 in) of rigid polyurethane foam panel would be required.

  5. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    To account for other components in a wall such as framing, first calculate the U-value (= 1/R-value) of each component, then the area-weighted average U-value. An average R-value is 1/(average U-value). For example, if 10% of the area is 4 inches of softwood (R-value 5.6) and 90% is 2 inches of silica aerogel (R-value 20), the area-weighted U ...

  6. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load. These include the global coordinates of the site and the size of the structure. [1] [5]

  7. Kingspan Group - Wikipedia

    en.wikipedia.org/wiki/Kingspan_Group

    One circularity target is to upcycle 1 billion PET bottles into insulation by 2025, up from 256 million in 2018. [70] In 2023, the company reported a 26 per cent reduction in carbon emissions since 2020. [71] Kingspan Group have over 120 manufacturing sites, which are spread across 70 different countries. [72]

  8. Curtain wall (architecture) - Wikipedia

    en.wikipedia.org/wiki/Curtain_wall_(architecture)

    While these curtain wall systems are more energy-efficient than older, single-glazed versions, they are still significantly less efficient than opaque (solid) wall construction. [13] For example, nearly all curtain wall systems, thermally-broken or otherwise, have a U-value of 0.2 or higher, which is equivalent to an R-value of 5 or lower. [14]

  9. Reference designator - Wikipedia

    en.wikipedia.org/wiki/Reference_designator

    1A1A44J5 - Unit 1, Assembly 1, Sub-Assembly 44, Jack 5 (J5 is a connector on a box referenced as A44) 1A1A45J333 - Unit 1, Assembly 1, Sub-Assembly 45, Jack 333 (J333 is a connector on a box referenced as A45) A cable connecting these two might be: 1A1W35 - In the assembly A1 is a cable called W35. Connectors on this cable would be designated ...