enow.com Web Search

  1. Ads

    related to: 1 hour fire rated interior wall assembly

Search results

  1. Results from the WOW.Com Content Network
  2. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    There are three main classifications of fire rated walls: fire walls, fire barriers, and fire partitions. A firewall is an assembly of materials used to delay the spread of fire a wall assembly with a prescribed fire resistance duration and independent structural stability. This allows a building to be subdivided into smaller sections.

  3. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Fire-resistance rated wall assembly with fire door, cable tray penetration and intumescent cable coating. Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. [1]

  4. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    This rating is the requirement in data safes and vault structures for protecting digital information on magnetic media or hard drives. Temperatures inside the protected chamber must be held below 125 °F (52 °C) for the time period specified, such as Class 125-2 Hour, with temperatures up to 2,000 °F (1,090 °C) outside the vault.

  5. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke. [1]

  6. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    Fire-resistance rated door, with wire mesh glass vision panel Industrial grade fire door rated to hydrocarbon curve and blast resistance Double fire door immediately after 3-hour fire test inside a 4-hour rated Durasteel wall Double fire door after 3-hour fire test in a 4-hour Durasteel wall, during successful 45PSI (3.1 bar) hose stream test leading to a UL Listing [1]

  7. Gypsum block - Wikipedia

    en.wikipedia.org/wiki/Gypsum_block

    A gypsum block is made of gypsum plaster and water. The manufacturing process [1] is automated at production plants where raw gypsum (CaSO 4 ·2H 2 O) is ground and dried, then heated to remove three-quarters of the bound water and thus transformed into calcium sulfate hemihydrate (CaSO 4 ·½H 2 O), also known as gypsum plaster, stucco, calcined gypsum or plaster of Paris.

  1. Ads

    related to: 1 hour fire rated interior wall assembly