enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  3. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The equations for the use of the data retrieved from these tables are very simple. Q= heat gain, usually heat gain per unit time A= surface area. U= Overall heat transfer coefficient. CLTD= cooling load temperature difference SCL= solar cooling load factor CLF= cooling load factor SC= shading coefficient

  5. Thermal conductivity and resistivity - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_and...

    The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]

  6. Thermal conductance and resistance - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductance_and...

    The SI unit of absolute thermal resistance is kelvins per watt (K/W) or the equivalent degrees Celsius per watt (°C/W) – the two are the same since the intervals are equal: ΔT = 1 K = 1 °C. The thermal resistance of materials is of great interest to electronic engineers because most electrical components generate heat and need to be cooled.

  7. List of thermal conductivities - Wikipedia

    en.wikipedia.org/wiki/List_of_thermal_conductivities

    Higashi anomalies: The very high c values that are labeled as thermal conductivities in table III on page 100 would roughly fit the thesis of the paper if they came with lower orders of magnitude. The way that the dry soils get a lot lighter between Table I on page 99 and table IV on pages 102-3 is eventually explained by the fact that Table I ...

  8. Window insulation - Wikipedia

    en.wikipedia.org/wiki/Window_insulation

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  9. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    The units of an R-value (see below) are usually not explicitly stated, and so it is important to determine from context which units are being used: an R-value expressed in I-P (inch-pound) units [13] is about 5.68 times larger than when expressed in SI units, [14] so that, for example, a window that is R-2 in I-P units has an RSI of 0.35 (since ...