enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pressure drop - Wikipedia

    en.wikipedia.org/wiki/Pressure_drop

    Pressure drop (often abbreviated as "dP" or "ΔP") [1] is defined as the difference in total pressure between two points of a fluid carrying network. A pressure drop occurs when frictional forces, caused by the resistance to flow, act on a fluid as it flows through a conduit (such as a channel, pipe , or tube ).

  3. Hagen–Poiseuille equation - Wikipedia

    en.wikipedia.org/wiki/Hagen–Poiseuille_equation

    In both cases, laminar or turbulent, the pressure drop is related to the stress at the wall, which determines the so-called friction factor. The wall stress can be determined phenomenologically by the Darcy–Weisbach equation in the field of hydraulics, given a relationship for the friction factor in terms of the Reynolds number. In the case ...

  4. Darcy–Weisbach equation - Wikipedia

    en.wikipedia.org/wiki/Darcy–Weisbach_equation

    If the formula for laminar flow is f = ⁠ 16 / Re ⁠, it is the Fanning factor f, and if the formula for laminar flow is f D = ⁠ 64 / Re ⁠, it is the Darcy–Weisbach factor f D. Which friction factor is plotted in a Moody diagram may be determined by inspection if the publisher did not include the formula described above:

  5. Kozeny–Carman equation - Wikipedia

    en.wikipedia.org/wiki/Kozeny–Carman_equation

    The Kozeny–Carman equation (or Carman–Kozeny equation or Kozeny equation) is a relation used in the field of fluid dynamics to calculate the pressure drop of a fluid flowing through a packed bed of solids. It is named after Josef Kozeny and Philip C. Carman.

  6. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    The Hazen–Williams equation is an empirical relationship that relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [ 1 ] such as fire sprinkler systems , [ 2 ] water supply networks , and irrigation systems.

  7. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.

  8. Darcy's law - Wikipedia

    en.wikipedia.org/wiki/Darcy's_law

    In the integral form, the total pressure drop = is in units (), and is the length of the sample in units (), the Darcy's volumetric flow rate , or discharge, is also defined in units (/) and the cross-sectional area in units (). A number of these parameters are used in alternative definitions below.

  9. Darcy friction factor formulae - Wikipedia

    en.wikipedia.org/wiki/Darcy_friction_factor_formulae

    The following table lists historical approximations to the Colebrook–White relation [23] for pressure-driven flow. Churchill equation [ 24 ] (1977) is the only equation that can be evaluated for very slow flow (Reynolds number < 1), but the Cheng (2008), [ 25 ] and Bellos et al. (2018) [ 8 ] equations also return an approximately correct ...