Search results
Results from the WOW.Com Content Network
EN 54 part 11 is the section of the mandatory standard relating to manual call points. European Committee for Standardization (CEN, French: Comité Européen de Normalisation ) is responsible for the development and maintenance of the standard, as part of its remit for developing harmonized European standards for free movement of goods in the ...
Thus, a dynamic call graph can be exact, but only describes one run of the program. A static call graph is a call graph intended to represent every possible run of the program. The exact static call graph is an undecidable problem, so static call graph algorithms are generally overapproximations. That is, every call relationship that occurs is ...
Manually actuated devices, also known as fire alarm boxes, manual pull stations, or simply pull stations, break glass stations, and (in Europe) call points, are installed to be readily located (usually near the exits of a floor or building), identified, and operated. They are usually actuated using physical interaction, such as pulling a lever ...
Using the Smith chart, the normalised impedance may be obtained with appreciable accuracy by plotting the point representing the reflection coefficient treating the Smith chart as a polar diagram and then reading its value directly using the characteristic Smith chart scaling. This technique is a graphical alternative to substituting the values ...
Campbell Diagram of a steam turbine. Analysis shows that there are well-damped critical speed at lower speed range. Analysis shows that there are well-damped critical speed at lower speed range. Another critical speed at mode 4 is observed at 7810 rpm (130 Hz) in dangerous vicinity of nominal shaft speed, but it has 30% damping - enough to ...
The radar chart is a chart and/or plot that consists of a sequence of equi-angular spokes, called radii, with each spoke representing one of the variables. The data length of a spoke is proportional to the magnitude of the variable for the data point relative to the maximum magnitude of the variable across all data points.
It is common practice in diagrams to draw a line under the lead end to assist in understanding the method. Most methods have a plain course consisting of a number of leads where the pattern is the same, but different bells are in differing places. In the diagram given, the number 4 bell rings the same pattern as the number 2, but one lead earlier.
Some CFG examples: (a) an if-then-else (b) a while loop (c) a natural loop with two exits, e.g. while with an if...break in the middle; non-structured but reducible (d) an irreducible CFG: a loop with two entry points, e.g. goto into a while or for loop A control-flow graph used by the Rust compiler to perform codegen.