Secondary chemical reference substance: substance whose characteristics are assigned and/or calibrated by comparison with a primary chemical reference substance. The United States National Institute of Standards and Technology (NIST) uses the trade marked term [ 12 ] Standard Reference Material (SRM) to denote a certified reference material ...
Before using a triple beam balance, the scale pointer should be at zero. [6] The zero adjustment knob can be used to adjust the scale pointer. Place the objects on the pan and adjust the riders until the scale pointer is at zero again, and then sum the weights marked (e.g. the 4th notch of 100 gram beam is 400g) to find the weight of the sample.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The Baumé scale is a pair of hydrometer scales developed by French pharmacist Antoine Baumé in 1768 to measure density of various liquids. The unit of the Baumé scale has been notated variously as degrees Baumé, B°, Bé° and simply Baumé (the accent is not always present). One scale measures the density of liquids heavier than water and ...
operations at the pilot plant scale, e.g., carried out by process chemists, which, though at the lowest extreme of manufacturing operations, are on the order of 200- to 1000-fold larger than laboratory scale, and used to generate information on the behavior of each chemical step in the process that might be useful to design the actual chemical ...
Vernier caliper scales; main at top, vernier at bottom. It reads 3.58 ± 0.02 mm by adding 3.00 mm (left red mark) on the fixed main scale to vernier 0.58 mm (right red mark). The main scale reading is that to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales.
In most indicating instruments, the accuracy is guaranteed to a certain percentage of full-scale reading. The limits of these deviations from the specified values are known as limiting errors or guarantee errors. [6]
Pointers - The scale pointer marks the equal point of the object's mass on the scale and mass on the beam; Zero adjustment knob - This is used to manually adjust the triple beam balance to the 'zero' mark (check to ensure that the pointer is at zero before use). Before using triple beam balance, the scale pointer should be at zero.