Search results
Results from the WOW.Com Content Network
The wet-bulb globe temperature (WBGT) is a measure of environmental heat as it affects humans. Unlike a simple temperature measurement, WBGT accounts for all four major environmental heat factors: air temperature, humidity, radiant heat (from sunlight or sources such as furnaces), and air movement (wind or ventilation). [ 1 ]
The wet-bulb temperature is the lowest temperature that may be achieved by evaporative cooling of a water-wetted, ventilated surface.. By contrast, the dew point is the temperature to which the ambient air must be cooled to reach 100% relative humidity assuming there is no further evaporation into the air; it is the temperature where condensation (dew) and clouds would form.
A sustained wet-bulb temperature of about 35 °C (95 °F) can be fatal to healthy people; at this temperature our bodies switch from shedding heat to the environment, to gaining heat from it. [10] Thus a wet bulb temperature of 35 °C (95 °F) is the threshold beyond which the body is no longer able to adequately cool itself. [11]
As the planet continues to get hotter, humans are at greater risk for heat-related illness and death but an index aims to avoid such.
T a is dry-bulb temperature (°C) RH is relative humidity (%) exp represents the exponential function; The Australian formula includes the important factor of humidity and is somewhat more involved than the simpler North American wind chill model. The North American formula was designed to be applied at low temperatures (as low as −46 °C or ...
If a gaseous emission sample is analyzed and found to contain water vapor and a pollutant concentration of say 40 ppmv, then 40 ppmv should be designated as the "wet basis" pollutant concentration. The following equation can be used to correct the measured "wet basis" concentration to a " dry basis " concentration: [ 3 ]
Metric (SI): Using a dry bulb of 25 °C and a wet bulb of 20 °C, read the relative humidity at approximately 63.5%. U.S/Imperial (IP): Using a dry bulb of 77 °F and a wet bulb of 68 °F, read the relative humidity at approximately 63.5%. In this example the humidity ratio is 0.0126 kg water per kg dry air.
Wet-bulb potential temperature, sometimes referred to as pseudo wet-bulb potential temperature, is the temperature that a parcel of air at any level would have if, starting at the wet-bulb temperature, it were brought at the saturated adiabatic lapse rate to the standard pressure of 1,000 mbar.