The precision of a measurement system, related to reproducibility and repeatability, is the degree to which repeated measurements under unchanged conditions show the same results. [3] [4] Although the two words precision and accuracy can be synonymous in colloquial use, they are deliberately contrasted in the context of the scientific method.
Because of the complex inter-relationship between analytical method, sample concentration, limits of detection and method precision, the management of Analytical Quality Control is undertaken using a statistical approach to determine whether the results obtained lie within an acceptable statistical envelope.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
Quality control (QC) is a measure of precision, or how well the measurement system reproduces the same result over time and under varying operating conditions. Laboratory quality control material is usually run at the beginning of each shift, after an instrument is serviced, when reagent lots are changed, after equipment calibration, and ...
In analytical chemistry, the detection limit, lower limit of detection, also termed LOD for limit of detection or analytical sensitivity (not to be confused with statistical sensitivity), is the lowest quantity of a substance that can be distinguished from the absence of that substance (a blank value) with a stated confidence level (generally 99%).
In information retrieval, the positive predictive value is called precision, and sensitivity is called recall. Unlike the Specificity vs Sensitivity tradeoff, these measures are both independent of the number of true negatives, which is generally unknown and much larger than the actual numbers of relevant and retrieved documents.
Spurious digits that arise from calculations resulting in a higher precision than the original data or a measurement reported with greater precision than the instrument's resolution. A zero after a decimal (e.g., 1.0) is significant, and care should be used when appending such a decimal of zero.
When using the triple beam balance, it is recommended that one start with the lowest level of precision (e.g 100 gram increments). For example, if an object weighs 327 grams, the 100 gram pointer will drop below the fixed mark on the 4th notch (400g); it will then need to be moved back to the third notch (300g).