enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    Single-wire earth return (SWER) or single-wire ground return is a single-wire transmission line which supplies single-phase electric power from an electrical grid to remote areas at lowest cost. The earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire ) to act as a ...

  3. Earth-return telegraph - Wikipedia

    en.wikipedia.org/wiki/Earth-return_telegraph

    Earth-return telegraph is the system whereby the return path for the electric current of a telegraph circuit is provided by connection to the earth through an earth electrode. Using earth return saves a great deal of money on installation costs since it halves the amount of wire that is required, with a corresponding saving on the labour ...

  4. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    In single-wire earth return (SWER) AC electrical distribution systems, costs are saved by using just a single high voltage conductor for the power grid, while routing the AC return current through the earth. This system is mostly used in rural areas where large earth currents will not otherwise cause hazards.

  5. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    Single-wire earth return (SWER) or single-wire ground return is a single-wire transmission line for supplying single-phase electrical power to remote areas at low cost. It is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. Single-wire earth return is also used for HVDC over submarine ...

  6. Transmission line - Wikipedia

    en.wikipedia.org/wiki/Transmission_line

    A transmission line is drawn as two black wires. At a distance x into the line, there is current I(x) travelling through each wire, and there is a voltage difference V(x) between the wires. If the current and voltage come from a single wave (with no reflection), then V(x) / I(x) = Z 0, where Z 0 is the characteristic impedance of the line.

  7. Single-wire transmission line - Wikipedia

    en.wikipedia.org/wiki/Single-wire_transmission_line

    The single-wire transmission line is not the same as the single-wire earth return system, which is not covered in this article. The latter system relies on a return current through the ground, using the earth as a second conductor between ground terminal electrodes. In a single-wire transmission line there is no second conductor of any form.

  8. Ground-coupled heat exchanger - Wikipedia

    en.wikipedia.org/wiki/Ground-coupled_heat_exchanger

    An alternative to the earth-to-air heat exchanger is the "water" to earth heat exchanger. This is typically similar to a geothermal heat pump tubing embedded horizontally in the soil (or could be a vertical sonde) to a similar depth of the earth-air heat exchanger. It uses approximately double the length of pipe of 35 mm diameter, e.g., around ...

  9. Stray voltage - Wikipedia

    en.wikipedia.org/wiki/Stray_voltage

    The term "stray voltage" is used for the gradient (rate of change with respect to distance) of electrical potential in the surface of the soil, associated with single-wire earth return electricity distribution systems used in some rural locations. This gradient is low at points far away from the earth return connections, but increases near the ...