enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Biosensor - Wikipedia

    en.wikipedia.org/wiki/Biosensor

    Biosensors used for screening combinatorial DNA libraries. In a biosensor, the bioreceptor is designed to interact with the specific analyte of interest to produce an effect measurable by the transducer. High selectivity for the analyte among a matrix of other chemical or biological components is a key requirement of the bioreceptor.

  3. Bio-layer interferometry - Wikipedia

    en.wikipedia.org/wiki/Bio-layer_interferometry

    Bio-layer interferometry platforms achieve high throughput by utilizing a "Dip and Read" format. [1] The biosensor tips themselves are transported directly to the desired sample and "dipped" into their respective compartment, eliminating the needs for micro-fluidics and the complications (clogging, purification) that come with it.

  4. Bio-FET - Wikipedia

    en.wikipedia.org/wiki/Bio-FET

    Bio-FETs couple a transistor device with a bio-sensitive layer that can specifically detect bio-molecules such as nucleic acids and proteins. A Bio-FET system consists of a semiconducting field-effect transistor that acts as a transducer separated by an insulator layer (e.g. SiO 2) from the biological recognition element (e.g. receptors or probe molecules) which are selective to the target ...

  5. MicroRNA biosensors - Wikipedia

    en.wikipedia.org/wiki/MicroRNA_Biosensors

    Stability of miRNA Biosensor: The stability of miRNA biosensors is compromised by environmental conditions, particularly for components like aptamers and antibodies. This issue is especially pertinent for point-of-care (POC) devices, which require robustness and longevity to be effectively used in various settings.

  6. Electrochemical aptamer-based biosensors - Wikipedia

    en.wikipedia.org/wiki/Electrochemical_aptamer...

    Electrochemical aptamer-based (E-AB) biosensors is a device that takes advantage of the electrochemical and biological properties of aptamers to take real time, in vivo measurements. An electrochemical aptamer-based (E-AB) biosensor generates an electrochemical signal in response to specific target binding in vivo [ 3 ] The signal is measured ...

  7. Bioinstrumentation - Wikipedia

    en.wikipedia.org/wiki/Bioinstrumentation

    At the end, this wire contains enzymes to take a small blood sample which uses NAD+ to oxidize glucose into gluconolactone and NAD+ into NADH. This NADH then breaks down in the blood into NAD+, a H+ ion, and two floating electrons which create a small signal, approximately 1 mV, sensed by the wire and displayed by the device the transmitter is ...

  8. Optogenetic methods to record cellular activity - Wikipedia

    en.wikipedia.org/wiki/Optogenetic_methods_to...

    The first experiments to measure intracellular calcium levels via protein expression were based on aequorin, a bioluminescent protein from the jellyfish Aequorea. To produce light, however, this enzyme needs the 'fuel' compound coelenteracine, which has to be added to the preparation. This is not practical in intact animals, and in addition ...

  9. Nicotinamide adenine dinucleotide - Wikipedia

    en.wikipedia.org/wiki/Nicotinamide_adenine_di...

    The actual concentration of NAD + in cell cytosol is harder to measure, with recent estimates in animal cells ranging around 0.3 mM, [18] [19] and approximately 1.0 to 2.0 mM in yeast. [20] However, more than 80% of NADH fluorescence in mitochondria is from bound form, so the concentration in solution is much lower. [21]