enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Biosensor - Wikipedia

    en.wikipedia.org/wiki/Biosensor

    Biosensors used for screening combinatorial DNA libraries. In a biosensor, the bioreceptor is designed to interact with the specific analyte of interest to produce an effect measurable by the transducer. High selectivity for the analyte among a matrix of other chemical or biological components is a key requirement of the bioreceptor.

  3. Bio-layer interferometry - Wikipedia

    en.wikipedia.org/wiki/Bio-layer_interferometry

    Bio-layer interferometry platforms achieve high throughput by utilizing a "Dip and Read" format. [1] The biosensor tips themselves are transported directly to the desired sample and "dipped" into their respective compartment, eliminating the needs for micro-fluidics and the complications (clogging, purification) that come with it.

  4. Bio-FET - Wikipedia

    en.wikipedia.org/wiki/Bio-FET

    Bio-FETs couple a transistor device with a bio-sensitive layer that can specifically detect bio-molecules such as nucleic acids and proteins. A Bio-FET system consists of a semiconducting field-effect transistor that acts as a transducer separated by an insulator layer (e.g. SiO 2) from the biological recognition element (e.g. receptors or probe molecules) which are selective to the target ...

  5. Watch Your Kids Experiment and Learn With These Editor ... - AOL

    www.aol.com/best-science-kits-kids-213500763.html

    Simple Machines Science Experiment and Model Building Kit. This is the best science for kids who love to tinker—you know, the one who takes things apart and puts them back together. There are 26 ...

  6. Electrochemical aptamer-based biosensors - Wikipedia

    en.wikipedia.org/wiki/Electrochemical_aptamer...

    Electrochemical aptamer-based (E-AB) biosensors is a device that takes advantage of the electrochemical and biological properties of aptamers to take real time, in vivo measurements. An electrochemical aptamer-based (E-AB) biosensor generates an electrochemical signal in response to specific target binding in vivo [ 3 ] The signal is measured ...

  7. Immunoassay - Wikipedia

    en.wikipedia.org/wiki/Immunoassay

    The active enzyme reduces NAD (no signal) to NADH (which absorbs at 340 nm), so absorbance is monitored at 340 nm. When the labeled analyte binds to the Ab, the enzyme becomes inactive, and a signal is generated by the free label. The signal intensity is directly proportional to the analyte concentration. [19]

  8. MicroRNA biosensors - Wikipedia

    en.wikipedia.org/wiki/MicroRNA_Biosensors

    The dynamic range in miRNA biosensors refers to the concentrations over which the biosensor can accurately detect the target miRNAs, extending from the lowest detectable LoD to the maximum concentration that can be measured without necessitating sample dilution.

  9. Nicotinamide adenine dinucleotide - Wikipedia

    en.wikipedia.org/wiki/Nicotinamide_adenine_di...

    The actual concentration of NAD + in cell cytosol is harder to measure, with recent estimates in animal cells ranging around 0.3 mM, [18] [19] and approximately 1.0 to 2.0 mM in yeast. [20] However, more than 80% of NADH fluorescence in mitochondria is from bound form, so the concentration in solution is much lower. [21]