enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. List of instruments used in microbiological sterilization and ...

    en.wikipedia.org/wiki/List_of_instruments_used...

    Koch's or Arnold's steam sterilizer: used for steam sterilization A pressure cooker: used as a portable autoclave Biological and chemical indicators: Used to ascertain if a certain process has been completed, e.g. spores used in an autoclave are killed if autoclaving is properly done Filters: •Candle filter:

  3. Infection prevention and control - Wikipedia

    en.wikipedia.org/wiki/Infection_prevention_and...

    Sterilization using steam can also be done at a temperature of 132 C (270 F), at a double pressure. [citation needed] Dry heat sterilization is performed at 170 C (340 F) for one hour or two hours at a temperature of 160 C (320 F). Dry heat sterilization can also be performed at 121 C, for at least 16 hours. [17]

  4. Autoclave - Wikipedia

    en.wikipedia.org/wiki/Autoclave

    An autoclave is a machine used to carry out industrial and scientific processes requiring elevated temperature and pressure in relation to ambient pressure and/or temperature. Autoclaves are used before surgical procedures to perform sterilization and in the chemical industry to cure coatings and vulcanize rubber and for hydrothermal synthesis ...

  5. Central sterile services department - Wikipedia

    en.wikipedia.org/wiki/Central_sterile_services...

    Sterile dental instruments from hospital central supply (barcoded label indicating sterilization date, expiry date and contents). The central sterile services department (CSSD), also called sterile processing department (SPD), sterile processing, central supply department (CSD), or central supply, is an integrated place in hospitals and other health care facilities that performs sterilization ...

  6. Aseptic processing - Wikipedia

    en.wikipedia.org/wiki/Aseptic_processing

    Equipment used in aseptic processing of food and beverages must be sterilized before processing and remain sterile during processing. [1] When designing aseptic processing equipment there are six basic requirements to consider: the equipment must have the capability of being cleaned thoroughly, it must be able to be sterilized with steam, chemicals, or high-temperature water, sterilization ...

  7. Sterilization (microbiology) - Wikipedia

    en.wikipedia.org/wiki/Sterilization_(microbiology)

    Proper autoclave treatment will inactivate all resistant bacterial spores in addition to fungi, bacteria, and viruses, but is not expected to eliminate all prions, which vary in their heat resistance. For prion elimination, various recommendations state 121–132 °C (250–270 °F) for 60 minutes or 134 °C (273 °F) for at least 18 minutes. [14]

  8. Center for Surveillance, Epidemiology and Laboratory Services

    en.wikipedia.org/wiki/Center_for_Surveillance...

    The Center for Surveillance, Epidemiology and Laboratory Services (CSELS) is a branch of the US Centers for Disease Control and Prevention (CDC) that provides scientific service, expertise, skills, and tools in support of national efforts to promote health; prevent disease, injury and disability; and prepare for emerging health threats. [1]

  9. Biosafety cabinet - Wikipedia

    en.wikipedia.org/wiki/Biosafety_cabinet

    The CDC does not recommend the installation of UV lamps in BSCs. [ 3 ] : 12–13 The American Biological Safety Association supports this position, citing the safety risk to personnel, shallow penetration, reduced effectiveness in high relative humidity , and the frequent need to clean and replace the bulb. [ 11 ]