A condensate pump is a specific type of pump used to pump the condensate produced in an HVAC (heating or cooling), refrigeration, condensing boiler furnace, or steam system. [ 1 ] Applications
Fire Protection Gas Suppression System [41] Fire Sprinkler Monitoring [42] Gas leak detectors [43] Globe Valve & Actuator [44] Honeywell Excel Series [45] Honeywell's Smart Home Security Starter Kit [46] Honeywell Guest Room Control [47] Honeywell Public Address and Voice Alarm (PAVA) products [48] Honeywell Pulse for Connected Buildings [49 ...
Control of the system's fan capacity is critical in VAV systems. Without proper and rapid flow rate control, the system's ductwork, or its sealing, can easily be damaged by overpressurization. In the cooling mode of operation, as the temperature in the space is satisfied, a VAV box closes to limit the flow of cool air into the space.
Feedwater pumps range in size up to many kilowatts and the electric motor is usually separated from the pump body by some form of mechanical coupling. Large industrial condensate pumps may also serve as the feedwater pump. In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam ...
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
Bypass humidifiers are connected between the heated and cold air return ducts, using the pressure difference between these ducts to cause some heated air to make a bypass through the humidifier and return to the furnace. Any humidifiers should usually be disabled during the summer months if air conditioning is used; air conditioners partially ...
Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space. The control circuit in a household HVAC installation.
At the bottom of the shell, where the condensate collects, an outlet is installed. In some designs, a sump (often referred to as the hotwell) is provided. Condensate is pumped from the outlet or the hotwell for reuse as boiler feedwater. For most water-cooled surface condensers, the shell is under [partial] vacuum during normal operating ...