enow.com Web Search

  1. Ads

    related to: hvac returns in every room at 2 months and 3 lines of service are available

Search results

  1. Results from the WOW.Com Content Network
  2. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    During winter months, for example, an air conditioning register can be closed to prevent cold air from being pulled from the room. This allows the hot air to mix more completely with the cold air in the room, improving the efficiency of the HVAC system. [7] (The return should be efficient enough to draw off the cooler air.) [10] [11]

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The respective tables of data were generally developed by using the more complex transfer function method to determine the various cooling loads for different types of heating. [2] [3] The results gained by doing so are then normalized for each type of heat gain used for the tables, CLTD, CLF, and SCL. [4]

  4. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Air returns from the room at ceiling level or the maximum allowable height above the occupied zone. [1] The UFAD system takes advantage of the thermal plume and stratification phenomenon: the conditioned air is supplied directly to the occupied zone (OZ). The thermal plumes generated by the occupants and other heat sources introduce the ...

  5. Diffuser (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Diffuser_(thermodynamics)

    A round diffuser in an HVAC system. Diffusers are very common in heating, ventilating, and air-conditioning systems. [3] Diffusers are used in both all-air and air-water HVAC systems, as part of room air distribution subsystems, and serve several purposes: To deliver both conditioning and ventilating air

  6. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  7. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).

  1. Ads

    related to: hvac returns in every room at 2 months and 3 lines of service are available