  1. Results from the WOW.Com Content Network
  2. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power-factor correction increases the power factor of a load, improving efficiency for the distribution system to which it is attached. Linear loads with a low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the ...

  3. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    An induction motor or asynchronous motor is an AC electric motor in which the electric ... Common bus power factor correction is recommended to minimize resonant risk ...

  4. Synchronous condenser - Wikipedia

    en.wikipedia.org/wiki/Synchronous_condenser

    An over-excited synchronous motor has a leading power factor. This makes it useful for power-factor correction of industrial loads. Both transformers and induction motors draw lagging (magnetising) currents from the line. On light loads, the power drawn by induction motors has a large reactive component and the power factor has a low value. The ...

  5. Rotary phase converter - Wikipedia

    en.wikipedia.org/wiki/Rotary_phase_converter

    Power-factor correction is a very important consideration when building or choosing an RPC. This is desirable because an RPC that has power-factor correction will consume less current from the single-phase service supplying power to the phase converter and its loads. A major concern with three phase power is that each phase be at similar voltages.

  6. Synchronous motor - Wikipedia

    en.wikipedia.org/wiki/Synchronous_motor

    Since most power systems of any significant size have a net lagging power factor, the presence of overexcited synchronous motors moves the system's net power factor closer to unity, improving efficiency. Such power-factor correction is usually a side effect of motors already present in the system to provide mechanical work, although motors can ...

  7. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found. It is very important to know a motor's starting torque since if it is not enough to overcome the initial friction of its intended load then it will remain stationary while drawing an ...

  8. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    The power frequency and voltage are not self regulating. The generator is able to supply current out of phase with the voltage requiring more external equipment to build a functional isolated power system. Similar is the operation of the induction motor in parallel with a synchronous motor serving as a power factor compensator.

  9. Voltage optimisation - Wikipedia

    en.wikipedia.org/wiki/Voltage_optimisation

    The latter includes power that is unusable, so a power factor of 1 is desirable. A low power factor would mean that the electricity supplier would effectively supply more energy than the consumer's bill would indicate, and suppliers are allowed to charge for low power factors. Reactive power is the name given to unusable power. It does no work ...