This x-intercept is also referred to as aligning prism or – in earlier times – as associated phoria when the subjective nonius method was used (sP 0) the slope of the curve near zero prism load; Fig. 3: Fixation disparity as a function of the forced vergence angle which is induced by base-in prisms and base-out prisms in front of the eyes.
The strength of the prism is increased until the streak of the light passes through the centre of the prism, as the strength of the prism indicates the amount of deviation present. The Maddox rod is a handheld instrument composed of red parallel plano convex cylinder lens , which refracts light rays so that a point source of light is seen as a ...
The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision (BSV) in the presence of increasing vergence demands. Motor fusion is largely accounted to ...
Specialty. Ophthalmology. Exotropia is a form of strabismus where the eyes are deviated outward. It is the opposite of esotropia and usually involves more severe axis deviation than exophoria. People with exotropia often experience crossed diplopia. Intermittent exotropia is a fairly common condition. "Sensory exotropia" occurs in the presence ...
Exophoria. Exophoria is a form of heterophoria in which there is a tendency of the eyes to deviate outward. [1] During examination, when the eyes are dissociated, the visual axes will appear to diverge away from one another. [2] The axis deviation in exophoria is usually mild compared with that of exotropia.
Some cases of convergence insufficiency are successfully managed by prescription of eyeglasses, sometimes with therapeutic prisms. Pencil push-ups therapy is performed at home. The patient brings a pencil slowly to within 2–3 cm (0.79–1.18 in) of the eye just above the nose about fifteen minutes per day five times per week.
The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]
The eye drifts upward spontaneously or after being covered. [1] The condition usually affects both eyes, but can occur unilaterally or asymmetrically. It is often associated with latent or manifest-latent nystagmus and, as well as occurring with infantile esotropia , can also be found associated with exotropias and vertical deviations.