enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. ASHRAE 90.1 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_90.1

    ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...

  3. United States building energy codes - Wikipedia

    en.wikipedia.org/wiki/United_States_building...

    ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]

  4. Reflective surfaces (climate engineering) - Wikipedia

    en.wikipedia.org/wiki/Reflective_surfaces...

    In Climate Zones 4 and above the recommendation is to follow the ASHRAE 90.1 standard for roof reflectance, which does not require roofs to be reflective in these zones. In Climate Zones 4 and above, Cool Roofs are not a recommended Design Strategy. [39]

  5. IDA Indoor Climate and Energy - Wikipedia

    en.wikipedia.org/wiki/IDA_Indoor_Climate_and_Energy

    IDA Indoor Climate and Energy (IDA ICE) is a Building performance simulation (BPS) software. IDA ICE is a simulation application for the multi-zonal and dynamic study of indoor climate phenomena as well as energy use. The implemented models are state of the art, many studies show that simulation results and measured data compare well. [1] [2] [3]

  6. International Green Construction Code - Wikipedia

    en.wikipedia.org/wiki/International_Green...

    The IgCC was designed to be used alongside other codes and standards, such as the International Energy Conservation Code (IECC) and ASHRAE 90.1, and is the result of a partnership between the public and private sectors. It is intended to provide a uniform green code that can be adopted by governments without the need for them to incur the cost ...

  7. Lighting power density - Wikipedia

    en.wikipedia.org/wiki/Lighting_power_density

    Space By Space Method. A defined list of many possible space types within a building the associated watts per square foot allowance. For example, ANSI/ASHRAE/IESNA Standard 90.1-2007 allows the Emergency Space of a hospital to be designed for 2.7 watts per square foot, but the Recovery areas of a hospital would be allowed 0.8 watts per square foot.

  8. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    There are two major systems to classify ductwork airtightness, one based on European standards, the other based on ASHRAE standard 90.1-2010.Both are based on the leakage airflow rate at a given ductwork pressure divided by the product of the ductwork surface area and the same ductwork pressure raised to the power 0.65.

  9. ASHRAE - Wikipedia

    en.wikipedia.org/wiki/ASHRAE

    ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]