Standard dimension ratio (SDR) is a method of rating a pipe's durability against pressure. The standard dimension ratio describes the correlation between the pipe dimension and the thickness of the pipe wall. [1] Common nominations are SDR11, SDR17, SDR26 and SDR35. Pipes with a lower SDR can withstand higher pressures.
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
Iron Pipe Size (IPS or I.P.S.) pipe sizing system based on the inside diameter (ID) of pipe. It was widely used from the early 19th century to the mid 20th century and is still in use by some industries, including major PVC pipe manufacturers, as well as for some legacy drawings and equipment.
British Standard Pipe Parallel Thread Dimensions; British Standard Pipe Taper Thread Dimensions Archived 2017-09-27 at the Wayback Machine; BSP Thread Charts and Diagrams, showing dimensions of tubing and fittings; ISO 7-1:1994; ISO 7-2:2000; ISO 228-1:2000; ISO 228-2:1987; Parallel pipe threads G; Parallel pipe threads PF
For pipe sizes of NPS 14 inch (DN 350) and greater the NPS size is the actual diameter in inches and the DN size is equal to NPS times 25 (not 25.4) rounded to a convenient multiple of 50. For example, NPS 14 has an OD of 14 inches or 355.60 millimetres, and is equivalent to DN 350.
While pipe sizes in Australia are inch-based, they are classified by outside rather than inside diameter (e.g., a nominal 3 ⁄ 4 inch copper pipe in Australia has measured diameters of 0.750 inches outside and 0.638 inches inside, whereas a nominal 3 ⁄ 4 inch copper pipe in the U.S. and Canada has measured diameters of 0.875 inch outside and ...
The energy consumed in manufacturing ductile iron pipe was 19.55 MJ per kg and volume of emissions released during manufacture was 1.430 kg CO 2 per kg, compared to 68.30 MJ per kg of energy and 4.860 kg CO 2 per kg emissions for PVC pipes, and 1.24 MJ per kg and 0.148 kg CO 2 per kg for concrete pipes of the same diameter.
Section 3 does not allow any construction approval of the Inspector of Plumbing and Drainage. A written description of the proposed work is to be submitted in advance to the inspector for his approval. Section 16 mandates the use of cast iron for interior pipes and Section 12 mandates the use of "vitrified stone ware pipes" that "run under ...