A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
Earth fault protection also requires current transformers and senses an imbalance in a three-phase circuit. Normally the three phase currents are in balance, i.e. roughly equal in magnitude. If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance.
Low voltage and low current signals (i.e., at the secondary of a voltage transformers and current transformers) are brought into a low pass filter that removes frequency content above about 1/3 of the sampling frequency (a relay A/D converter needs to sample faster than twice per cycle of the highest frequency that it is to monitor).
The ELCB detects fault currents between line and earth (ground) conductors within the portion of the installation it protects. If sufficient characteristics of a fault appear across the ELCB's sensing mechanism, then it will switch off the power , and remain off until manually reset.
In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. [ 1 ] : 4 The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, overvoltage , reverse power flow ...
60P - Phase Current Unbalance; 61 - Density Switch or Sensor; 62 - Time-Delay Stopping or Opening Relay; 63 - Pressure Switch Detector; 64 - Ground Protective Relay; 64F - Field Ground Protection; 64R – Rotor Earth Fault; 64REF – Restricted Earth Fault Differential; 64S – Stator Earth Fault; 64S - Sub-harmonic Stator Ground Protection ...