  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  3. Insulation monitoring device - Wikipedia

    en.wikipedia.org/wiki/Insulation_monitoring_device

    An insulation monitoring device monitors the ungrounded system between an active phase conductor and earth.It is intended to give an alert (light and sound) or disconnect the power supply when the resistance between the two conductors drops below a set value, usually 50 kΩ (sample of IEC standard for medical applications).

  4. Earth-leakage protection device - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    A wire break in the fault to load section, or in the earth to ground section, will disable operation of the devices. Requirement of an additional third wire from the load to the devices. Separate devices cannot be grounded individually. Any additional connection to Earth on the protected system can disable the detector.

  5. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Earth fault protection also requires current transformers and senses an imbalance in a three-phase circuit. Normally the three phase currents are in balance, i.e. roughly equal in magnitude. If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance.

  6. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.

  7. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    Provide a relatively low-impedance path to ground, thereby maintaining the system neutral at or near ground potential. [3] Limit the magnitude of transient over voltages when restriking ground faults occur. Provide a source of ground fault current during line-to-ground faults. Permit the connection of phase-to-neutral loads when desired. [2]

  8. Ground continuity monitor - Wikipedia

    en.wikipedia.org/wiki/Ground_continuity_monitor

    A GCM or ground continuity monitor (also called a ground integrity monitor or ground continuity tester) is an electrical safety device that monitors the impedance to ground of a temporary electrical circuit and can provide indication (or protective trip) in the event impedance rises to an unsafe value. A GCM is either an external testing device ...

  9. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Its purpose was to protect lighting circuit wiring from accidental short circuits and overloads. A modern miniature circuit breaker similar to the ones now in use was patented by Brown, Boveri & Cie in 1924. Hugo Stotz, an engineer who had sold his company to Brown, Boveri & Cie, was credited as the inventor on German patent 458392. [3]