enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Nameplate capacity - Wikipedia

    en.wikipedia.org/wiki/Nameplate_capacity

    Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others.

  3. Table of specific heat capacities - Wikipedia

    en.wikipedia.org/wiki/Table_of_specific_heat...

    For example, Paraffin has very large molecules and thus a high heat capacity per mole, but as a substance it does not have remarkable heat capacity in terms of volume, mass, or atom-mol (which is just 1.41 R per mole of atoms, or less than half of most solids, in terms of heat capacity per atom).

  4. Nominal power (photovoltaic) - Wikipedia

    en.wikipedia.org/wiki/Nominal_power_(photovoltaic)

    The nominal power of PV devices is measured under standard test conditions (STC), specified in standards such as IEC 61215, IEC 61646 and UL 1703. Specifically, the light intensity is 1000 W/m 2, with a spectrum similar to sunlight hitting the Earth's surface at latitude 35°N in the summer (airmass 1.5), the temperature of the cells being 25 °C.

  5. Capacity credit - Wikipedia

    en.wikipedia.org/wiki/Capacity_credit

    The capacity credit can be much lower than the capacity factor (CF): in a not very probable scenario, if the riskiest time for the power system is after sunset, the capacity credit for solar power without coupled energy storage is zero regardless of its CF [3] (under this scenario all existing conventional power plants would have to be retained after the solar installation is added).

  6. Energy storage - Wikipedia

    en.wikipedia.org/wiki/Energy_storage

    Storage capacity is the amount of energy extracted from an energy storage device or system; usually measured in joules or kilowatt-hours and their multiples, it may be given in number of hours of electricity production at power plant nameplate capacity; when storage is of primary type (i.e., thermal or pumped-water), output is sourced only with ...

  7. Design load - Wikipedia

    en.wikipedia.org/wiki/Design_load

    A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) [1] = The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than =.(p 84) [1] Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, = = The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope ...

  8. Flamanville Nuclear Power Plant - Wikipedia

    en.wikipedia.org/wiki/Flamanville_Nuclear_Power...

    Unit 3 is an EPR unit with a nameplate capacity of 1.65 GW e connected to the grid in December 2024 [2] (but still far from full power as of January 2025). The power plant produced 18.9 TWh in 2005, which amounted to 4% of the electricity production in France.

  9. Diablo Canyon Power Plant - Wikipedia

    en.wikipedia.org/wiki/Diablo_Canyon_Power_Plant

    Thermal capacity: 2 × 3411 MW th: Power generation; Units operational: 1 × 1138 MW 1 × 1118 MW: Make and model: WH 4-loop (DRYAMB) Nameplate capacity: 2256 MW: Capacity factor: 90.93% (2017) 87.25% (lifetime) Annual net output: 17,718 GWh (2023) [4] External links; Website: Diablo Canyon Power Plant: Commons: Related media on Commons