Search results
Results from the WOW.Com Content Network
Pile integrity testing using low-strain tests such as the TDR (Transient Dynamic Response) method, is a rapid way of assessing the continuity and integrity of concrete piled foundations. The test measures: pile length, or depth to anomalies; pile head stiffness; pile shaft mobility, which is dependent on pile section and concrete properties
Crosshole sonic logging (CSL) is a method to determine the structural integrity of drilled shafts and other concrete piles. The CSL method is considered to be more accurate than sonic echo testing in the determination of structural soundness of concrete within the drilled shaft inside of the rebar cage.
Dynamic load testing takes a further step in analyzing the data and computing static capacity and resistance distribution. Dynamic pile monitoring takes advantage of the fact that, for driven piles, it is possible to compute the energy delivered to the pile, compression stresses at the pile top and toe and tension stresses along the shaft.
Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...
The day after Christmas offers three college football bowl games as you recover from opening presents. A look at the three matchups.
Manufacturers of baby powder and cosmetic products made with talc will have to test them for asbestos under a proposal announced by the U.S. Food and Drug Administration.
Get answers to your AOL Mail, login, Desktop Gold, AOL app, password and subscription questions. Find the support options to contact customer care by email, chat, or phone number.
The testing method was first developed in the mid 1990s at the University of South Florida. [1] [2] It relates the heat generated by curing of cement to the integrity and quality of drilled shafts, augered cast in place (ACIP) piles and other concrete foundations. In general, a shortage of competent concrete (necks or inclusions) is registered ...