Search results
Results from the WOW.Com Content Network
The concepts of signal-to-noise ratio and dynamic range are closely related. Dynamic range measures the ratio between the strongest un-distorted signal on a channel and the minimum discernible signal, which for most purposes is the noise level. SNR measures the ratio between an arbitrary signal level (not necessarily the most powerful signal ...
The noise power from a simple load is equal to kTB, where k is the Boltzmann constant, T is the absolute temperature of the load (for example a resistor), and B is the measurement bandwidth. This makes the noise figure a useful figure of merit for terrestrial systems, where the antenna effective temperature is usually near the standard 290 K ...
Ampex tape recorders in the 1950s achieved 60 dB in practical usage, [26] In the 1960s, improvements in tape formulation processes resulted in 7 dB greater range, [28]: 158 and Ray Dolby developed the Dolby A-Type noise reduction system that increased low- and mid-frequency dynamic range on magnetic tape by 10 dB, and high-frequency by 15 dB ...
The noise equivalent bandwidth (or equivalent noise bandwidth (enbw)) of a system of frequency response is the bandwidth of an ideal filter with rectangular frequency response centered on the system's central frequency that produces the same average power outgoing () when both systems are excited with a white noise source. The value of the ...
Friis formula or Friis's formula (sometimes Friis' formula), named after Danish-American electrical engineer Harald T. Friis, is either of two formulas used in telecommunications engineering to calculate the signal-to-noise ratio of a multistage amplifier. One relates to noise factor while the other relates to noise temperature.
Cosmic noise has been observed in a range from 8 MHz to 1.43 GHz, the latter frequency corresponding to the 21-cm hydrogen line. Apart from man-made noise, it is the strongest component over the range of about 20 to 120 MHz.
Expressed in decibels, the dynamic range is 20 log (Vmax/Vmin). For example, a device with an input range of ±10 V and a dynamic range of 110 dB will be able to measure a signal as small as 10 μV. Thus, the input range and the specified dynamic range are important for determining the needs of your instrumentation system.
The noise factor (a linear term) is more often expressed as the noise figure (in decibels) using the conversion: = The noise figure can also be seen as the decrease in signal-to-noise ratio (SNR) caused by passing a signal through a system if the original signal had a noise temperature of 290 K. This is a common way of expressing the noise ...