CT scanning can perform a virtual colonoscopy with greater accuracy and less discomfort for the patient than a traditional colonoscopy. [143] [144] Virtual colonography is far more accurate than a barium enema for detection of tumors and uses a lower radiation dose. [145] CT is a moderate-to-high radiation diagnostic technique.
Low-dose high-resolution (1.25 mm) chest CT. HRCT is performed using a conventional CT scanner. However, imaging parameters are chosen so as to maximize spatial resolution: [1] a narrow slice width is used (usually 1–2 mm), a high spatial resolution image reconstruction algorithm is used, field of view is minimized, so as to minimize the size of each pixel, and other scan factors (e.g. focal ...
As with any test that screens for disease, the risks of full-body CT scans need to be weighed against the benefit of identifying a treatable disease at an early stage. [6] An alternative to a full-body CT scan may be Magnetic resonance imaging (MRI) scans. MRI scans are generally more expensive than CT but do not expose the patient to ionizing ...
Abdominal imaging is associated with many potential uses for the different phases of contrast CT.The majority of abdominal and pelvic CT's can be performed using a single-phase, but the evaluation of some tumor types (hepatic/pancreatic/renal), the urinary collecting system, and trauma patients among others, may be best performed with multiple phases.
In conventional CT machines, an X-ray tube and detector are physically rotated behind a circular shroud (see the image above right). An alternative, short lived design, known as electron beam tomography (EBT), used electromagnetic deflection of an electron beam within a very large conical X-ray tube and a stationary array of detectors to achieve very high temporal resolution, for imaging of ...
Electron beam CT scanners are considered a fifth generation CT scanner, with first generation being the pencil beam with translation and rotation, second generation being a fan beam with similar motion to its predecessor, third generation having both rotating fan beam and detectors and fourth generation being a fan beam with a rotating movement but fixed detector.
When a photon interacts in a PCD, the amplitude of the resulting electrical pulse is roughly proportional to the photon energy. By comparing each pulse produced in a pixel with a suitable low-energy threshold, contributions from low-energy events (resulting from both photon interactions and electronic noise) can be filtered out.
Computed tomography angiography (also called CT angiography or CTA) is a computed tomography technique used for angiography—the visualization of arteries and veins—throughout the human body. Using contrast injected into the blood vessels, images are created to look for blockages, aneurysms (dilations of walls), dissections (tearing of walls ...