enow.com Web Search

  1. Ads

    related to: 100 amp eaton disconnect

Search results

  1. Results from the WOW.Com Content Network
  2. Disconnector - Wikipedia

    en.wikipedia.org/wiki/Disconnector

    In electrical engineering, a disconnector, disconnect switch or isolator switch is a type of switching device with visible contacts, used to ensure that an electrical circuit is completely de-energized for service or maintenance.

  3. Camlock (electrical) - Wikipedia

    en.wikipedia.org/wiki/Camlock_(electrical)

    Camlock is generally used where temporary connections of 3-phase and/or more than 50 A are needed. Applications include connecting large temporary generators or load banks to distribution panels or building disconnects. Common scenarios include testing, emergencies, temporary special events, and traveling stage shows with large lighting and ...

  4. Motor control center - Wikipedia

    en.wikipedia.org/wiki/Motor_control_center

    Motor control centers are usually used for low voltage three-phase alternating current motors from 208 V to 600 V. Medium-voltage motor control centers are made for large motors running at 2300 V to around 15000 V, using vacuum contactors for switching and with separate compartments for power switching and control.

  5. FASTON terminal - Wikipedia

    en.wikipedia.org/wiki/FASTON_terminal

    These terminals are manufactured by many companies, commonly using the terms "quick disconnect", "quick connect", "tab" terminals, "spade" terminals [1] or blade connectors; without qualifiers, the first two could be mistaken for plumbing connections. [2]

  6. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  7. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    An example of an inrush current transient during a 100 VA toroid transformer energization. Inrush peak around 50 times of nominal current. Inrush current can be divided in three categories: Energization inrush current result of re-energization of transformer. The residual flux in this case can be zero or depending on energization timing.

  1. Ads

    related to: 100 amp eaton disconnect