Ads
related to: understanding circuit breaker markings chart
Search results
Results from the WOW.Com Content Network
A reference designator unambiguously identifies the location of a component within an electrical schematic or on a printed circuit board.The reference designator usually consists of one or two letters followed by a number, e.g. C3, D1, R4, U15.
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...
out 2. flasher circuit 49c out 3. flasher circuit C 1st flasher indicator light K, K1, P C2 2nd flasher indicator light K1, K2, K3, K4 C3 3rd flasher indicator light K3, K4 L indicator lights left HL, L54, VL R indicator lights right HR, R54, VR L54 lights out, left SBL R54 lights out, right SBR AC generator; 51 DC at rectifiers: 51e
In electric power systems and industrial automation, ANSI Device Numbers can be used to identify equipment and devices in a system such as relays, circuit breakers, or instruments. The device numbers are enumerated in ANSI / IEEE Standard C37.2 Standard for Electrical Power System Device Function Numbers, Acronyms, and Contact Designations .
Arc-Fault Circuit Interrupter (AFCI) protection is required to protect nearly all finished areas of a home with the exception of bathrooms. This device, which can be a circuit breaker or the first outlet on a circuit, is designed to detect hazardous electrical arcing in the branch circuit wiring as well as in cords and plugs.
A circuit diagram (or: wiring diagram, electrical diagram, elementary diagram, electronic schematic) is a graphical representation of an electrical circuit. A pictorial circuit diagram uses simple images of components, while a schematic diagram shows the components and interconnections of the circuit using standardized symbolic representations.
Each phase of the circuit is run in a separate grounded metal enclosure. The only fault possible is a phase-to-ground fault, since the enclosures are separated. This type of bus can be rated up to 50,000 amperes and up to hundreds of kilovolts (during normal service, not just for faults), but is not used for building wiring in the conventional ...
A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.
Ads
related to: understanding circuit breaker markings chart