Search results
Results from the WOW.Com Content Network
V = volume of air in ml passing through the specimen; H = Height of the specimen in cm; A = Cross sectional area of specimen in cm2; P = Pressure of air in cm of water; T = Time in minutes; American Foundry Society has also released a chart where back pressure (P) from a rammed specimen placed on a permeability meter is correlated with a ...
The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.
ISO standard 1133-1 governs the procedure for measurement of the melt flow rate. [5] The procedure for determining MFI is as follows: A small amount of the polymer sample (around 4 to 5 grams) is taken in the specially designed MFI apparatus. A die with an opening of typically around 2 mm diameter is inserted into the apparatus.
The test involves filling the vessel or pipe system with a liquid, usually water, which may be dyed to aid in visual leak detection, and pressurization of the vessel to the specified test pressure. Pressure tightness can be tested by shutting off the supply valve and observing whether there is a pressure loss.
V T is the bulk volume of the sample, V a is the volume of the container containing the sample, V b is the volume of the evacuated container, P 1 is the initial pressure in the initial pressure in volume V a and V V, and P 2 is final pressure present in the entire system. The porosity follows straightforwardly by its proper definition
This means that a much shorter column is needed compared to water. [2] For instance, the pressure represented by a column of 100 mm of water is just under 7.4 mm of mercury . [3] The pressure is determined by measuring the difference in height between the reference column and the column connected to the item under test.
First, a static pressure gauge is attached to the test hydrant and the static water pressure is measured at the test hydrant. Second, the flow hydrant opened to allow water to flow in a fully open condition. Simultaneously the pitot tube pressure is recorded from the flow hydrant while the residual pressure is measured from the test hydrant.
The California Department of Transportation has developed a similar test, California Test 216, which measures the maximum wet density, and controls the compactive effort based on the length (in fact the height) of the test sample and not on its volume. The primary advantage of this test is that maximum density test results are available sooner ...