Ad
related to: intumescent fire dampers for ductwork- Fire Protection
Fire Sprinkler Parts
Fire Sprinkler Pipe
- 1" Ball Valve
1" Ball Valve
Fire Protection
- Fire Sprinkler
Viking
White Pendent 1/2" 5.6K 155F
- Fire Sprinkler Penden
VK Chrome Pendent
1/2" 5.6K 155F
- Fire Protection
Search results
Results from the WOW.Com Content Network
Intumescent dampers swell shut due to intumescence in the event of a fire. Unlike mechanical dampers, it is a physical/chemical reaction that causes closure. Cleaning and an age assessment are periodically performed. The annulus of an intumescent damper is closed eliminating smoke migration. Also, intumescent fire dampers can be qualified to ...
Smoke damper may be used to prevent the spread of smoke from the space of fire origin to other spaces in the same building. A combination of fans and dampers can exhaust smoke from an area while pressurizing the smoke-free areas around the affected area (inhibiting smoke infiltration into additional areas).
These intumescent materials produce a light char which is a poor conductor of heat, thus retarding heat transfer.Typically the light char consists of microporous carbonaceous foam formed by a chemical reaction of three main components: ammonium polyphosphate, pentaerythritol, and melamine. [2]
Exceptions are fire dampers (fire-resistive closures within air ducts, excluding grease ducts) and fire door closers, which move, open and shut in order to work, as well as all intumescent products which swell in order to provide adequate material thickness and fill gaps.
There are two means of providing fire-resistance rated ductwork: Inherently fire-resistant, or proprietary factory assembled ducts which are made of sheet metal shells filled with mixtures of rockwool, fiber and silicon dioxide; Sheet metal duct with exterior fireproofing materials such as blanket rockwool, ceramic fiber, or intumescent paint.
Fire dampers are fitted where ductwork passes through fire compartment walls and fire curtains as part of a fire control strategy. In normal circumstances, these dampers are held open by means of fusible links. When subjected to heat, these links fracture and allow the damper to close under the influence of the integral closing spring.
Smoke exhaust ductwork, in Europe, is typically protected via passive fire protection means, subject to fire testing (typically to NBN EN 1366-8 [1]) and listing and approval use and compliance. It is used to remove smoke from buildings , ships or offshore structures to enable emergency evacuation as well as improved firefighting.
In the event of a fire, a smoke control system is used to keep a building's escape routes and access routes free from smoke, assist fire-fighting operations and delay or prevent flashover, thereby reducing the risk that the fire will escalate. [1]