enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    In this case, only reactive power flows: There is no net transfer of energy to the load; however, electrical power does flow along the wires and returns by flowing in reverse along the same wires. The current required for this reactive power flow dissipates energy in the line resistance, even if the ideal load device consumes no energy itself.

  3. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Electrical loads consuming alternating current power consume both real power and reactive power. The vector sum of real and reactive power is the complex power, and its magnitude is the apparent power. The presence of reactive power causes the real power to be less than the apparent power, and so, the electric load has a power factor of less ...

  4. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    The goal of a power-flow study is to obtain complete voltage angles and magnitude information for each bus in a power system for specified load and generator real power and voltage conditions. [3] Once this information is known, real and reactive power flow on each branch as well as generator reactive power output can be analytically determined.

  5. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    However, once the generator's operating point reaches the corners of the D-curve, increasing the reactive power output will require reduction of the real (active) power. Since the electricity markets payments are typically based on real power, the generating company will have a disincentive to provide more reactive power if requested by the ...

  6. Maximum power transfer theorem - Wikipedia

    en.wikipedia.org/wiki/Maximum_power_transfer_theorem

    For a fixed reactive source, the maximum power theorem maximizes the real power (P) delivered to the load by complex conjugate matching the load to the source. For a fixed reactive load , power factor correction minimizes the apparent power (S) (and unnecessary current) conducted by the transmission lines, while maintaining the same amount of ...

  7. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    In direct current (DC) circuits, this product is equal to the real power, measured in watts. [3] The volt-ampere is dimensionally equivalent to the watt: in SI units, 1 V⋅A = 1 W. VA rating is most used for generators and transformers, and other power handling equipment, where loads may be reactive (inductive or capacitive).

  8. Slack bus - Wikipedia

    en.wikipedia.org/wiki/Slack_bus

    However, power will be flowing out, thus, the real power and reactive power will be both negative. The Load Bus will be used to find the bus voltage and angle. PV bus – the real power | | and the voltage magnitude | | are specified. It is also known as Generator Bus. The real power and voltage are specified for buses that are generators.

  9. Power-voltage curve - Wikipedia

    en.wikipedia.org/wiki/Power-voltage_curve

    Power-voltage curve (also P-V curve) describes the relationship between the active power delivered to the electrical load and the voltage at the load terminals in an electric power system under a constant power factor. [1] When plotted with power as a horizontal axis, the curve resembles a human nose, thus it is sometimes called a nose curve. [2]