The PFA-100 (Platelet Function Assay [1] or Platelet Function Analyser [2]) is a platelet function analyser that aspirates blood in vitro from a blood specimen into disposable test cartridges through a microscopic aperture cut into a biologically active membrane at the end of a capillary.
Aspirin inhibits platelet function via the AA pathway while clopidogrel inhibits platelet function via the ADP pathway; thus, this test can be used to determine the degree to which a patient is anticoagulated due to either medication. In this assay, a standard TEG is run using patient's whole blood.
The ristocetin-induced platelet aggregation (RIPA) is an ex vivo assay for live platelet function. It measures platelet aggregation with the help of von Willebrand factor (vWF) and exogenous antibiotic ristocetin added in a graded fashion. [ 1 ]
Bleeding time is a medical test done to assess the function of a person's platelets. It involves making a patient bleed, then timing how long it takes for them to stop bleeding using a stopwatch or other suitable devices. The term template bleeding time is used when the test is performed to standardized parameters.
Multiplate multiple electrode aggregometry (MEA) is a test of platelet function in whole blood. [1] [2] The test can be used to diagnose platelet disorders, [3] [4] [5] monitor antiplatelet therapy, [6] and is also investigated as a potential predictor of transfusion requirements and bleeding risk in cardiac surgery. [7]
The PFA-100 (Platelet Function Assay — 100) is a system for analysing platelet function in which citrated whole blood is aspirated through a disposable cartridge containing an aperture within a membrane coated with either collagen and epinephrine or collagen and ADP. These agonists induce platelet adhesion, activation and aggregation, leading ...
INTEM This test mildly activates the contact phase of haemostasis. The result is influenced by coagulation factors, platelets, fibrinogen and heparin. Low molecular weight heparin is detected at higher concentrations. [15] [16] In the absence of heparin, INTEM is a screening test for the haemostasis system. It is used for therapeutic decisions ...
Enzyme activity is commonly used for e.g. liver function tests like AST, ALT, LD and γ-GT in Sweden. [5] Percentages and time-dependent units (mol/s) are used for calculated derived parameters, e.g. for beta cell function in homeostasis model assessment or thyroid's secretory capacity. [citation needed]