enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A shunt-trip unit appears similar to a normal breaker and the moving actuators are ganged to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or DC. These are often used to cut ...

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  4. List of CB slang - Wikipedia

    en.wikipedia.org/wiki/List_of_CB_slang

    Break/Breaker Informing other CB users that you would like to start a transmission on a channel. May be followed by either the channel number, indicating that anyone may acknowledge (e.g., "Breaker One-niner" refers to channel 19, the most widely used among truck drivers), or by a specific "handle", which is requesting a particular individual ...

  5. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    At two multiples of the rated current, the recloser's rapid trip curve can cause a trip (off circuit) in as little as 1.5 cycles (or 30 milliseconds). During those 1.5 cycles, other separate circuits can see voltage dips or blinks until the affected circuit opens to stop the fault current.

  6. Protective relay - Wikipedia

    en.wikipedia.org/wiki/Protective_relay

    In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. [ 1 ] : 4 The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, overvoltage , reverse power flow ...

  7. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    In electric power systems and industrial automation, ANSI Device Numbers can be used to identify equipment and devices in a system such as relays, circuit breakers, or instruments. The device numbers are enumerated in ANSI / IEEE Standard C37.2 Standard for Electrical Power System Device Function Numbers, Acronyms, and Contact Designations .

  8. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    This AFCI (the circuit breaker with the yellow label) is an older generation AFCI circuit breaker. The current (as of 2013) devices are referred to as "combination type." An arc-fault circuit interrupter ( AFCI ) or arc-fault detection device ( AFDD ) [ 1 ] is a circuit breaker that breaks the circuit when it detects the electric arcs that are ...

  9. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    A shunt is a device that is designed to provide a low-resistance path for an electrical current in a circuit.It is typically used to divert current away from a system or component in order to prevent overcurrent.