A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.
A calibration curve is obtained by measuring a series of standard solutions with known concentrations, which can be used to determine the concentration of an unknown sample using linear regression analysis. [12] For example, by comparing the absorbance values of a solution with an unknown concentration to a series of standard solutions with ...
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL) A general method for analysis of concentration involves the creation of a calibration curve. This allows for the determination of the amount of a chemical in a material by comparing the results of an unknown ...
When the total CO 2 content is significant, as in natural waters and alkaline effluents, two or three inflections can be seen in the pH-volume curves owing to buffering by higher concentrations of bicarbonate and carbonate. As discussed by Stumm and Morgan (1981), the analysis of such waters can use up to six Gran plots from a single titration ...
The analytical (total) concentration of a reactant R at the i th titration point is given by = + [] + where R 0 is the initial amount of R in the titration vessel, v 0 is the initial volume, [R] is the concentration of R in the burette and v i is the volume added. The burette concentration of a reactant not present in the burette is taken to be ...
Then, a small volume of standard solution is added and the response is measured again. Ideally, the standard addition should increase the analyte concentration by a factor of 1.5 to 3, and several additions should be averaged. The volume of standard solution should be small enough to disturb the matrix as little as possible.
The GPC sorts the polymer chains by volume and as intrinsic viscosity is related to the volume of the polymer chain, the GPC data is the same for the two different polymers. For example, if the GPC calibration curve is known for polystyrene in toluene , polyethylene in toluene can be run in a GPC and the molecular weight of polyethylene can be ...