Most regulatory authorities in the United States that offer requirements for flood openings define two major classes of opening: [1] engineered, and non-engineered. The requirements for non-engineered openings are typically stricter, defining necessary characteristics for aspects ranging from overall size of each opening, to allowable screening or other coverage options, to number and ...
The high point of the vent system (the top of its "soil stack") must be open to the exterior at atmospheric pressure. On large systems, separate parallel vent stacks may also be run to ensure sufficient airflow, because the number of devices linked to an atmospheric vent, and their distances from it, are regulated by plumbing code.
This is why UK Building Regulations require roofs to be ventilated, either by the use of soffit vents, ridge vents, or replacement ventilation slates or tiles. [7] A common method of ventilating a roof is to make openings in the soffit and ridge to allow natural air flow. This example also has ventilated exterior walls called rainscreen ...
Ventilation on the downdraught system, by impulsion, or the 'plenum' principle, applied to schoolrooms (1899) Natural ventilation is the ventilation of a building with outside air without using fans or other mechanical systems. It can be via operable windows, louvers, or trickle vents when spaces are small and the architecture permits.
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
As more architecture incorporated mechanical ventilation, the cost of outdoor air ventilation came under some scrutiny. In 1973, in response to the 1973 oil crisis and conservation concerns, ASHRAE Standards 62-73 and 62–81) reduced required ventilation from 10 CFM (4.76 L/s) per person to 5 CFM (2.37 L/s) per person. In cold, warm, humid, or ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Vents must be closed at night so radiant heat from the interior surface of the storage wall heats the indoor space. Generally, vents are also closed during summer months when heat gain is not needed. During the summer, an exterior exhaust vent installed at the top of the wall can be opened to vent to the outside.