enow.com Web Search

  1. Ads

    related to: grounding transformer sizing chart
    • Substation

      Request a quote for a substation

      In stock substation transformers

    • Get In Touch

      Contact Us Today

      Have Questions? We're Here To Help

    • Sell Your Transformer

      Get an offer for your transformer

      We buy new and used transformers

    • Contact Us

      Get In touch with us

      We look forward to hearing from you

Search results

  1. Results from the WOW.Com Content Network
  2. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    A grounding transformer. A grounding transformer or earthing transformer is a type of auxiliary transformer used in three-phase electric power systems to provide a ground path to either an ungrounded wye or a delta-connected system. [1] [2] Grounding transformers are part of an earthing system of the network.

  3. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.

  4. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    In the MEN system, the integrity of the neutral is paramount. In Australia, new installations must also bond the foundation concrete re-enforcing under wet areas to the protective earth conductor (AS3000), typically increasing the size of the earthing (i.e. reducing resistance), and providing an equipotential plane in areas such as bathrooms.

  5. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Any Δ-Y (delta-wye) connected transformer may be used for the purpose. A nine winding transformer (a "zig zag" transformer) may be used to balance the phase currents of a delta connected source with an unbalanced load. Low-resistance grounding systems use a neutral grounding resistor (NGR) to limit the fault current to 25 A or greater.

  6. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Parallel operations: All the transformers should have same phase rotation, vector group, tap setting & polarity of the winding. Ground fault Relay: A Dd transformer does not have neutral. To restrict the ground faults in such systems, we may use a zigzag wound transformer to create a neutral along with the ground fault relay.

  7. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    The output is a number of feeders. Distribution voltages are typically medium voltage, between 2.4 kV and 33 kV, depending on the size of the area served and the practices of the local utility. The feeders run along streets overhead (or underground, in some cases) and power the distribution transformers at or near the customer premises.

  8. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The neutral conductor is connected to ground at the transformer center tap. Circuits for lighting and small appliance power outlets use 120 V circuits connected between one line and neutral. High-demand applications, such as ovens, are often powered using 240 V AC circuits—these are connected between the two 120 V AC lines.

  9. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    Other advantages of autotransformers include lower leakage reactance, lower losses, lower excitation current, and increased VA rating for a given size and mass. [ 2 ] An example of an application of an autotransformer is one style of traveler's voltage converter , that allows 230-volt devices to be used on 120-volt supply circuits, or the reverse.

  1. Ads

    related to: grounding transformer sizing chart