  1. Results from the WOW.Com Content Network
  2. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    Hydraulic calculations indicate that the combination of the two primary components of a water based fire protection system will meet the design objectives to control, suppress, or extinguish a fire: The available water supply is sufficient in flowrate and pressure.

  3. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    A process to perform a water flow test is explained in the model fire codes as published by NFPA (National Fire Protection Association). If a water supply source is considered weak compared to what is required by the sprinkler system design hydraulic calculation, the water pressure can be boosted by means of a fire pump.

  4. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.

  5. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  6. Fire suppression system - Wikipedia

    en.wikipedia.org/wiki/Fire_suppression_system

    An Ansul fire suppression system in a hospital cafeteria Fire suppression systems are used to extinguish, control, or in some cases, entirely prevent fires from spreading or occurring. Fire suppression systems have an incredibly large variety of applications, and as such, there are many different types of suppression systems for different ...

  7. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    The Hazen–Williams equation is an empirical relationship that relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [1] such as fire sprinkler systems, [2] water supply networks, and irrigation systems.

  8. Compressed air foam system - Wikipedia

    en.wikipedia.org/wiki/Compressed_air_foam_system

    Air pressurized water (APW) fire extinguishers are commonly converted into makeshift CAFS extinguishers by drilling two 1/8-1/16 inch holes in the pickup tube above the water line. The unit is then filled with 1.5 US gallons (5.7 L) of water and class A foam, AFFF , FFFP or commercial detergent is added to the water in a 1% ratio for class A ...

  9. Standpipe (firefighting) - Wikipedia

    en.wikipedia.org/wiki/Standpipe_(firefighting)

    External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...