Search results
Results from the WOW.Com Content Network
Compared with the Cohn process, the albumin purity went up from about 95% to 98% using chromatography, and the yield increased from about 65% to 85%. Small percentage increases make a difference in regard to sensitive measurements like purity. There is one big drawback in using chromatography, which has to do with the economics of the process.
It means that to increase resolution of two peaks on a chromatogram, one of the three terms of the equation need to be modified. 1) N can be increased by lengthening the column (least effective, as doubling the column will get a 2 1/2 or 1.44x increase in resolution).
The prevailing method to increase the sensitivity of analytical methods has been multi-dimensional chromatography. This practice uses other analysis techniques in conjunction with liquid chromatography. For example, mass spectrometry (MS) has very much gained in popularity as an on-line analytical technique following HPLC.
Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds.
The Cohn process, developed by Edwin J. Cohn, is a series of purification steps with the purpose of extracting albumin from blood plasma.The process is based on the differential solubility of albumin and other plasma proteins based on pH, ethanol concentration, temperature, ionic strength, and protein concentration.
The discovery of a chemical present in blood that increases the risk of cancer would be a discovery that an analytical chemist might be involved in. An effort to develop a new method might involve the use of a tunable laser to increase the specificity and sensitivity of a spectrometric method. Many methods, once developed, are kept purposely ...
The setting of reasonable cutoff limits help reduce false positive results that occur from assay limitations. Because of the social and legal consequences, a positive test result must be confirmed by an alternative method, usually Gas Chromatography/Mass spectrometry.
Bioanalysis was traditionally thought of in terms of measuring small molecule drugs. However, the past twenty years has seen an increase in biopharmaceuticals (e.g. proteins and peptides), which have been developed to address many of the same diseases as small molecules. These larger biomolecules have presented their own unique challenges to ...