Search results
Results from the WOW.Com Content Network
Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.2 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and no Back-Cover Texts.
Rca (°C/W) = Thermal resistance of the Heat sink, between the case of the CPU and the ambient air. Tc = Maximum allowed temperature of the CPU's case (ensuring full performances). Ta = Maximum expected ambient temperature at the inlet of the Heat sink fan. All these parameters are linked together by the following equation:
A heat sink is not a device with the "magical ability to absorb heat like a sponge and send it off to a parallel universe". [2] Natural convection requires free flow of air over the heat sink. If fins are not aligned vertically, or if fins are too close together to allow sufficient air flow between them, the efficiency of the heat sink will ...
A finned air cooled heatsink with fan clipped onto a CPU, with a smaller passive heatsink without fan in the background A 3-fan heatsink mounted on a video card to maximize cooling efficiency of the GPU and surrounding components Commodore 128DCR computer's switch-mode power supply, with a user-installed 60 mm cooling fan.
Generally, forced convection heat sink thermal performance is improved by increasing the thermal conductivity of the heat sink materials, increasing the surface area (usually by adding extended surfaces, such as fins or foam metal) and by increasing the overall area heat transfer coefficient (usually by increase fluid velocity, such as adding ...
General purpose diagrams include: PV diagram; T–s diagram; h–s (Mollier) diagram; Psychrometric chart; Cooling curve; Indicator diagram; Saturation vapor curve; Thermodynamic surface; Specific to weather services, there are mainly three different types of thermodynamic diagrams used: Skew-T log-P diagram; Tephigram; Emagram; Stüve diagram
A water block is the watercooling equivalent of a heatsink. It is a type of plate heat exchanger and can be used on many different computer components, [1]: 186 including the central processing unit (CPU), GPU, PPU, and northbridge chipset on the motherboard. There are also Monoblocks on the market that are mounted on PC motherboards and cover ...
A thermal interface material (shortened to TIM) is any material that is inserted between two components in order to enhance the thermal coupling between them [1].A common use is heat dissipation, in which the TIM is inserted between a heat-producing device (e.g. an integrated circuit) and a heat-dissipating device (e.g. a heat sink).