enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    The test is typically performed over a range of test voltages from 0.5 Uo to 2 Uo depending on the standard/guide that is being followed. Apply VLF in order to detect and measure partial discharge . In this case, the IEEE 400.3 outlines a procedure for assessment and IEC 60270 provides the background for partial discharge testing of high ...

  3. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60172 Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires; IEC 60183 Guidance for the selection of high-voltage A.C. cable systems; IEC 60188 High-pressure mercury vapour lamps – Performance specifications; IEC 60189 Low-frequency cables and wires with PVC insulation and PVC sheath

  4. Cross-linked polyethylene - Wikipedia

    en.wikipedia.org/wiki/Cross-linked_polyethylene

    A cross-linked polyethylene (PEX) pipe. Cross-linked polyethylene, commonly abbreviated PEX, XPE or XLPE, is a form of polyethylene with cross-links.It is used predominantly in building services pipework systems, hydronic radiant heating and cooling systems, domestic water piping, insulation for high tension (high voltage) electrical cables, and baby play mats.

  5. High-voltage cable - Wikipedia

    en.wikipedia.org/wiki/High-voltage_cable

    High voltage is defined as any voltage over 1000 volts. [3] Those of 2 to 33 kV are usually called medium voltage cables, those over 50 kV high voltage cables.. Modern HV cables have a simple design consisting of a few parts: the conductor, the conductor shield, the insulation, the insulation shield, the metallic shield, and the jacket.

  6. Cable fault location - Wikipedia

    en.wikipedia.org/wiki/Cable_fault_location

    The conventionally used aid in cable fault testing and location is the cable test van. The van is installed with conventional cable measuring systems for quickly reaching the location of any cable fault. In 20 years that followed, over 2000 fault location vehicles were manufactured, more than half of which were intended for the former USSR.

  7. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    PVC-sheathed MICC cable. Conductor cross section area is 1.5 mm 2; overall diameter is 7.2 mm. Mineral-insulated cables at a panel board. Mineral-insulated copper-clad cable is a variety of electrical cable made from copper conductors inside a copper sheath, insulated by inorganic magnesium oxide powder.

  8. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    Prior to 2013 IS 201-4:2001 ( I.S. 201 part 4: PVC and Low Smoke Halogen Free Sheathed cables for fixed wiring) permitted both the UK style of twin and earth, and also a version with a CPC with a cross-section equal to that of the main conductors and insulated in green and yellow inside the full length of the cable.

  9. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    BS 6231 is a British Standard, last revised in 2006 by the BSI Group. [4] This standard specifies the performance and construction requirements of electrical cables that are single core, non-sheathed, PVC-insulated and rated 600/1000 V. Wire meeting the requirements of type CK of this standard is used as tri-rated wire.